Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
820-1-1D-48-32/300-48-080-6 Bottom Connection, ≤ 0.22% Full Scale Accuracy, 4 to 20 mA, Downscale Burnout, 1/2" National Pipe Thread (NPT) Sliding Compression, M 12 x 1 (5 pin) Connection, 8" Stem, 6" Immersion, 6 mm Diameter Digital Temperature Indicator |
820-1-1U-8--50/200C-48-025-2 Bottom Connection, ≤ 0.22% Full Scale Accuracy (Best Fit Straight Line (BFSL)), 4 to 20 mA, Upscale Burnout, 1/2" National Pipe Thread (NPT), M12 x 1 Connection, 2.5" Stem, 1/4" Diameter Digital Temperature Indicator |
||
Description |
N/A
|
|||
Type | N/A Temperature Indicator | |||
Connection Type | N/A Male National Pipe Thread (MNPT) with sliding compression fitting (Add 2" to stem length for this option) | N/A Male National Pipe Thread (MNPT) | ||
Probe Material | N/A 316 Stainless Steel in | |||
Display | N/A 4-digit LED, decimal point selectable by software | |||
Temperature Ranges [Min] | N/A 32 ºF | N/A 50 ºF | ||
Temperature Ranges [Max] | N/A 300 ºF | N/A 200 ºF | ||
Housing Material | N/A 316 Stainless Steel | |||
Connection Size | N/A 1/2 in | |||
Output Signal | N/A 4 mA to 20 mA | |||
Response Time | N/A 0.5 to 30 ms | |||
Electrical Connection | N/A M12 x 1 (5-pin) | |||
Power Supply | N/A 9-36 Vdc, polarity protected | |||
Accuracy | N/A ≤0.22% full scale | |||
Temperature Indicator | N/A Resistance Temperature Device (RTD) (PT100 DIN EN 60751, Class A) | |||
Series | N/A 820 Bottom connection | |||
Burnouts | N/A Downscale | N/A Upscale | ||
Pressure (On Probe) [Max] | N/A 500 psi | |||
Supply Effect | N/A 0.005%/V | |||
Power Consumption |
N/A
15 mA at 24 Vdc + output current - 950 mW max. 20 mA at 24 Vdc for PNP output - 500 mW max. 20 mA at 24 Vdc + sourcing current for NPN output 50 mA at 24 Vdc for relay output - 1,200 mW max. |
|||
Current Output | N/A 4 mA to 20 mA (3-wire configuration) linear to temperature | |||
Load on Current Output [Max] | N/A (Vsupply-9V ) / 20 mA, Ω | |||
Optional Switching Output |
N/A
Transistor Negative Positive Negative (NPN) (max 100 mA source ) or Transistor Positive Negative Positive (PNP) (max 100 mA sink) or Relay Single Pole Double Throw (SPDT) 0.5A at 240 Vac |
|||
Optional Switching Logic | N/A N.C. or N.O. software selectable | |||
Optional Switching Ranges | N/A Customer programmable between -325 ºF to 1,100 ºF (-200 ºC to 600 ºC) | |||
Isolation | N/A 500 Vdc input /output (between probe and output signal) | |||
Hysteresis | N/A 1% of range standard; customer programmable optional | |||
Open Circuit Detection |
N/A
Upscale (22 mA) or downscale (2.5 mA) current output. Error message on LED display |
|||
Warm Up | N/A 30 s | |||
Radio Frequency Interference (RFI) Effect | N/A 1% or less typical | |||
Effect | N/A <0.01% FS/ ºC | |||
Ambient Temperature Range | N/A -40 to 176 ºF-40 to 80 ºC | |||
Storage Temperature | N/A -58 to 185 ºF-50 to 85 ºC | |||
Warranty | N/A 3 yr | |||
Display Resolution | N/A ±0.02% F.S. ±1 digit | |||
Stem Diameters | N/A 6 mm | N/A 1/4 in | ||
Stem Lengths | N/A 8 in | N/A 2.5 in | ||
Application |
N/A
|
|||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||
Additional Information |
N/A
|
|||
Thermowells | N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. | |||
Related Items | N/A |
N/A
50-025-304-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 50-025-316-SS, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell 75-025-304-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell 75-025-316-SS, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell |
||
Note | N/A Thermowells are recommended for pressure, corrosive fluids and high velocity applications. | |||
|