Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
PT40-100psig-1-1-2-7 High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, DIN form C |
PT40-100psig-1-1-2-17 High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, DIN form C with 3 ft cable |
PT40-100psig-1-1-2-25 High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, M12 x 1 4 pin |
PT40-100psig-1-1-2-36 High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, integral cable 3 ft |
PT40-100psig-1-1-8-16 High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/2 NPT male, 1/2 NPT conduit with 3 ft cable |
|||||
Description | N/A High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, DIN form C | N/A High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, DIN form C with 3 ft cable | N/A High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, M12 x 1 4 pin | N/A High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/4 NPT male, integral cable 3 ft | N/A High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 1/2 NPT male, 1/2 NPT conduit with 3 ft cable | |||||
Pressure Range | N/A 0 to 100 psi gauge | |||||||||
Accuracy | N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | |||||||||
Output Signal | N/A 4 mA to 20 mA, 2-Wire | |||||||||
Process Connection | N/A 1/4 NPT male | N/A 1/4 NPT male | N/A 1/4 NPT male | N/A 1/4 NPT male | N/A 1/2 NPT male | |||||
Electrical Connection | N/A DIN form C | N/A DIN form C with 3 ft cable | N/A M12 x 1 4 pin | N/A integral cable 3 ft | N/A 1/2 NPT conduit with 3 ft cable | |||||
Power Requirement | N/A 10 Vdc to 30 Vdc | |||||||||
Environmental Rating | N/A IP65 | N/A IP65 | N/A IP67 | N/A IP68 | N/A IP68 | |||||
Materials of Construction (Wetted Parts) | N/A 316 Stainless Steel with 316 Stainless Steel housing | |||||||||
Media Temperature Range | N/A -20 to 212 ºF-30 to 100 ºC | |||||||||
|