MENU
NOSHOK'S COVID-19 Response
  • Gauge ranges from 23,000 psig to 145,000 psig
  • Current and voltage outputs available
  • Elgiloy and 17-4PH Stainless Steel wetted parts
  • CE compliant to suppress RFI, EMI and ESD
Unit of Measure
Items
PT41-6-16-Photograph

High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable

PT41-6-8-Photograph

High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A

PT41-6-14-Photograph

High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit

PT41-6-18-Photograph

High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable

PT41-6-25-Photograph

High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin
Description N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin
Pressure Range N/A 0 to 23000 psi gauge
Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions
Output Signal N/A 4 mA to 20 mA, 2-Wire
Process Connection N/A 9/16-18 UNF 2B high pressure
Electrical Connection N/A 1/2 NPT conduit with 3 ft cable N/A DIN form A N/A DIN form A with 1/2 NPT female conduit N/A DIN form A with 3 ft cable N/A M12 x 1 4 pin
Power Requirement N/A 10 Vdc to 30 Vdc
Environmental Rating N/A IP68 N/A IP65 N/A IP65 N/A IP65 N/A IP67
Materials of Construction (Wetted Parts) N/A 316 Stainless Steel with 316 Stainless Steel housing
Media Temperature Range N/A 32 to 175 ºF0 to 80 ºC