PT41-23000psig-1-1-6-16 High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable |
PT41-23000psig-1-1-6-8 High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A |
PT41-23000psig-1-1-6-14 High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit |
PT41-23000psig-1-1-6-18 High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable |
PT41-23000psig-1-1-6-25 High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin |
|||||
Description | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | |||||
Pressure Range | N/A 0 to 23000 psi gauge | |||||||||
Accuracy | N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | |||||||||
Output Signal | N/A 4 mA to 20 mA, 2-Wire | |||||||||
Process Connection | N/A 9/16-18 UNF 2B high pressure | |||||||||
Electrical Connection | N/A 1/2 NPT conduit with 3 ft cable | N/A DIN form A | N/A DIN form A with 1/2 NPT female conduit | N/A DIN form A with 3 ft cable | N/A M12 x 1 4 pin | |||||
Power Requirement | N/A 10 Vdc to 30 Vdc | |||||||||
Environmental Rating | N/A IP68 | N/A IP65 | N/A IP65 | N/A IP65 | N/A IP67 | |||||
Materials of Construction (Wetted Parts) | N/A 316 Stainless Steel with 316 Stainless Steel housing | |||||||||
Media Temperature Range | N/A 32 to 175 ºF0 to 80 ºC | |||||||||
|