Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
200V-3-1-5/25-vac-4 200V Series Snap Action, Brass Wetted Materials, NBR Diaphragm, 1 SPDT, (NO/NC), 1/8" NPT, -5 to -25 inHg (350 psig), Spade Terminals (1/4" x 1/32") Mechanical Compact SPDT Pressure Switch |
200V-3-1-5/25-vac-46 200V Series Snap Action, Brass Wetted Materials, NBR Diaphragm, 1 SPDT, (NO/NC), 1/8" NPT, -5 to -25 inHg (350 psig), Deutsch Integral 3-Pin (DT04-3P) Mechanical Compact SPDT Pressure Switch |
200V-3-1-5/25-vac-69 200V Series Snap Action, Brass Wetted Materials, NBR Diaphragm, 1 SPDT, (NO/NC), 1/8" NPT, -5 to -25 inHg (350 psig), M12 x 1 3-Pin Mechanical Compact SPDT Pressure Switch |
200V-3-1-5/25-vac-77 200V Series Snap Action, Brass Wetted Materials, NBR Diaphragm, 1 SPDT, (NO/NC), 1/8" NPT, -5 to -25 inHg (350 psig), 18" Flying Leads Mechanical Compact SPDT Pressure Switch |
200V-3-1-5/25-vac-101 200V Series Snap Action, Brass Wetted Materials, NBR Diaphragm, 1 SPDT, (NO/NC), 1/8" NPT, -5 to -25 inHg (350 psig), Deutsch 3-Pin Male (DT04-3P) Mechanical Compact SPDT Pressure Switch |
|||||
Description |
N/A
|
|||||||||
Type | N/A Mechanical Pressure Switch | |||||||||
Series | N/A 200 | |||||||||
Switching Function | N/A Single Pole Double Throw (SPDT) | |||||||||
Switch Adjustable Range | N/A -5 to -25 inHg | |||||||||
Electrical Connection | N/A Spade Terminals (1/4 x 1/32) | N/A Deutsch Integral 3-Pin (DT04-3P) | N/A M12 x 1 3-Pin | N/A 18 in. Flying Leads | N/A Deutsch 3-Pin Male (DT04-3P), Attached to Flying Leads | |||||
Process Connection | N/A National Pipe Thread (NPT) Male | |||||||||
Process Connection Size | N/A 1/8 in | |||||||||
Weight | N/A 0.2 lb | |||||||||
Housing Material | N/A Zinc-Nickel Plated Steel | |||||||||
Switch Type | N/A Snap Action | |||||||||
Environmental Rating | N/A Ingress Protection (IP00) | N/A Ingress Protection (IP69) | N/A Ingress Protection (IP69) | N/A Ingress Protection (IP69) | N/A Ingress Protection (IP69) | |||||
Non-Repeatability | N/A 1 psi or 5% of Setpoint | |||||||||
Contact Material | N/A Solid Silver, Self-Cleaning | |||||||||
Optional Contact Material | N/A Gold-Plated | |||||||||
Frequency [Max] | N/A 100 cpm | |||||||||
Switch Point | N/A Field Adjustable and/or Factory Set | |||||||||
Hysteresis | N/A 4 to 6 inHg | |||||||||
Service Life | N/A < 1,000,000 Load Cycles | |||||||||
Media Temperature Range | N/A -20 to 80 ºC-4 to 176 ºF | |||||||||
Ambient Temperature Range | N/A -20 to 80 ºC-4 to 176 ºF | |||||||||
Static Proof Pressure | N/A 9,000 psi620 bar | |||||||||
Dynamic Proof Pressure | N/A 7,500 psi517 bar | |||||||||
Vacuum Pressure Switch Adjustable Ranges | N/A -5 to -25 inHg | |||||||||
Measuring Element | N/A Brass, NBR Diaphragm | |||||||||
Warranty | N/A 1 yr | |||||||||
Application |
N/A
|
|||||||||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|||||||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. Gauge failures determined to be caused by over-range, incompatibility with environment or product media and abuse will not be considered under this warranty. NOSHOK, Inc. will, at its discretion, repair or replace the working parts of the damaged gauge without cost to the customer. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||||
Distribution Manifolds | N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. | |||||||||
Mechanical Switches Options & Accessories | N/A Factory Adjusted Switch Point (Specify) | |||||||||
Pressure Snubbers - Piston Type |
N/A
|
|||||||||
Pressure Snubbers - Sintered Type |
N/A
|
|||||||||
Steam Syphons |
N/A
|
|||||||||
Swivel Adapters |
N/A
|
|||||||||
Contact Rating | N/A 5A @ 12/24 Vdc 5A @ 125/250 Vac | |||||||||
|