Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Digital Indicator |
Series |
N/A 1900 |
Process Display |
N/A 5 digit, 0.48" liquid crystal display |
Operating Temperature [Min] |
N/A -35 ºC31 ºF |
Operating Temperature [Max] |
N/A 75 ºC167 ºF |
Input Signals |
N/A Voltage |
Accuracy |
N/A <0.1 % |
Storage Temperature |
N/A -31 to 185 ºF-35 to 85 ºC |
Effect |
N/A ≤0.1 % |
Full Scale Temperature |
N/A 18 ºF10 ºC |
Environmental Rating |
N/A National Electrical Manufacturers Association (NEMA) 4, National Electrical Manufacturers Association (NEMA) 4X, Ingress Protection (IP65) (Front of Display Only) |
Input Signals Current |
N/A 4 to 20 mA |
Input Signals Direct Current (DC) Voltage |
N/A 0 to 10 V |
Direct Current (DC) Voltage |
N/A 9 to 28 V |
Key Pad |
N/A 2 programmable function keys |
Typical Power Consumption |
N/A 10 mA |
Display Intensity Power Consumption [Max] |
N/A 95 mA |
Electrical Connection |
N/A Screw terminals at back of case |
Memory |
N/A Electrically Erasable Programmable Read-Only Memory (EEPROM) |
Non-Condensing Humidity |
N/A 85 % |
Vibration |
N/A 5 to 500 Hz5 g |
Shock |
N/A 30 g |
Normal Rejection Mode |
N/A 60 dB |
Normal Rejection Mode Frequency |
N/A 50 Hz60 Hz |
Altitude |
N/A Up to 2,000 m |
Update Rate |
N/A 500 ms |
Selectable Filtering |
N/A 0.25 to 1 s |
Linearization |
N/A 2 Point |
Display |
N/A Reflective |
Reading [Min/Max] |
N/A Captures and stores min/max measurement |
User Inputs |
N/A 1 programmable, 28 Vdc max. continuous |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326-1, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Weight |
N/A 3 oz |
Warranty |
N/A 2 yr |
Options |
N/A Resistance Temperature Device (RTD), Thermocouple |
Option Cards |
N/A
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Application |
N/A
|
Additional Information |
N/A
|
1950 Series Compact Smart System Digital Indicator Option Cards |
N/A
|
AC to DC Retrofit Package |
N/A
|
NEMA 4 Enclosure - 1950 Series Digital Indicator |
N/A
|