Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Submersible Level Transmitter |
Series |
N/A 611 |
Pressure Range1 | N/A 0 to 25 psig57.7 ftH2O |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
N/A ± 1.0% of span % |
Note for Accuracy |
N/A
Includes non-linearity, hysteresis, zero offset and end value deviation per IEC 61298-2 Accuracy after turndown via HART®, ≤ ±1.25% of scaled span (0.75% optional) Temperature sensor 14 ºF to 176 ºF (-10 ºC to 80 ºC): ≤ ± 3.3 ºF. |
Output Signal |
N/A 4 mA to 20 mA, 2-Wire and Hart® Signal |
Process Connections |
N/A Nose Cone |
Electrical Connection |
N/A Standard Polyurethane (PUR) Cable, Optional Water-Blocked Polyvinyl Chloride (PVC) Cable (200+ psi Only), Optional Fluorinated Ethylene Propylene (FEP) Cable (38) |
Options |
N/A Cable Clamp |
Style |
N/A Level Transmitter |
Approximate Weight |
N/A 10.6 oz |
Storage Temperature [Min] |
N/A -40 ºC-40 ºF |
Storage Temperature [Max] |
N/A 80 ºC176 ºF |
Optional Accuracy |
N/A ± 0.5 of span |
Optional Housing Material |
N/A 318 LN |
Warranty |
N/A 3 yr |
Stability |
N/A ≤ ± 0.1% of span per year |
Switch on Time (Output signals without HART®) |
N/A ≤ 150 ms |
Switch on Time (Output Signals with HART®) |
N/A ≤ 250 ms |
Settling Time (Output Signals without HART®) |
N/A ≤ 100 ms |
Settling Time (Output Signals with HART®) |
N/A ≤ 250 ms |
Durability |
N/A < 100,000,000 full scale cycles |
Power Requirement2 |
N/A
4mA to 20 mA: 8 Vdc to 36 Vdc 4 mA to 20 mA and HART®: 12-36 Vdc 0.1 to 2.5 Vdc: 3.6 - 36 Vd |
Load Limitations |
N/A
4 mA to 20 mA: ≤ (Vpower - 8 V) / 0.022 A 4 mA to 20 mA and HART®: ≤ (Vpower - 9.6 V) / 0.022 A |
Proof Pressure |
N/A 5 Times Range |
Measuring Element |
N/A
Cap: Polyvinylidene Fluoride (PVDF) Sensor: 316 stainless steel, options Hastelloy C-276 Cable: Polyurethane, optional FEP |
Connection Material |
N/A 316 Stainless Steel |
Housing Material |
N/A 316 Stainless Steel |
Environmental Rating |
N/A Ingress Protection (IP68) |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Electrical Protection |
N/A Reverse polarity protection, short circuit and resistance to overvoltage :DC 40V and increased overvoltage for lightning protection. Normal discharge current ≤ 10 kA, Rise time 8/20 µs |
Submersion Depth [Max] |
N/A 325 ft100 m |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A 4 g |
Cable Length |
N/A 150 ft |
Compensated Temperature Range |
N/A 32 to 176 ºF0 to 80 ºC |
Note for Compensated Temperature Range |
N/A Effect ± 0.01%/ºF for zero and span |
Standard Media Temperature Range |
N/A 14 to 122 ºF-10 to 50 ºC |
Optional Media Temperature Range |
N/A -40 to 176 ºF-40 to 80 ºC |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Application |
N/A
|
Additional Information |
N/A
|
Options and Accessories |
N/A
|