Items |
204-93-47/470inH2O-1-43-28-TC 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" NPT Female Sanitary Transmitter with Transparent Cover |
204-93-47/470inH2O-1-43-71-TC 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover |
204-93-6/58-1-43-28-TC 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" National Pipe Thread (NPT) Female Sanitary Transmitter with Transparent Cover |
204-93-6/58-1-43-71-TC 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover |
204-95-47/470inH2O-1-43-28-TC 20 Series King Gage Standard - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" National Pipe Thread (NPT) Female Sanitary Transmitter with Transparent Cover |
|||||
Description |
N/A
|
|||||||||
Type | N/A Sanitary Pressure Transmitter | |||||||||
Weight | N/A 3.3 lb | |||||||||
Storage Temperature [Min] | N/A -20 ºC-4 ºF | |||||||||
Storage Temperature [Max] | N/A 100 ºC212 ºF | |||||||||
Housing Material | N/A 304 Stainless Steel | |||||||||
Output Signal | N/A 4 mA to 20 mA, 2-Wire and HART® Signal | |||||||||
Electrical Connection | N/A 1/2 in. National Pipe Thread (NPT) Female | N/A PG9 cable gland | N/A 1/2 in. National Pipe Thread (NPT) Female | N/A PG9 cable gland | N/A 1/2 in. National Pipe Thread (NPT) Female | |||||
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) | N/A 0.1% of Adjusted Span % | |||||||||
Environmental Rating | N/A Ingress Protection (66) (National Electrical Manufacturers Association (NEMA) 4X), Ingress Protection (68) (National Electrical Manufacturers Association (NEMA) 6) optional | |||||||||
Series | N/A 20 | |||||||||
Process Connections | N/A Anderson Negele Type SL Long - 6 in. | N/A Anderson Negele Type SL Long - 6 in. | N/A Anderson Negele Type SL Long - 6 in. | N/A Anderson Negele Type SL Long - 6 in. | N/A King Gauge Standard - 6 in. | |||||
Connection Material | N/A 316 Stainless Steel | |||||||||
Adjustable Pressure Range | N/A 47 to 470 inH2O1.7 to 17 psig | N/A 47 to 470 inH2O1.7 to 17 psig | N/A 160 to 1,600 inH2O6 to 58 psig | N/A 160 to 1,600 inH2O6 to 58 psig | N/A 47 to 470 inH2O1.7 to 17 psig | |||||
Stability | N/A < 0.1%/year | |||||||||
Adjustment | N/A By 3 push buttons on display or optional Hart® signal | |||||||||
Response Time | N/A <150 ms | |||||||||
Service Life | N/A 10 yr | |||||||||
Measuring Element | N/A 316 Stainless Steel (Hastelloy C, Tantalum or Goldplated optional) | |||||||||
Temperature Range for 45 Minute | N/A 145 ºC293 ºF | |||||||||
Direct Current (DC) Voltage | N/A 12 to 36 V | |||||||||
Options | N/A Transparent Cover (for Display) (TC) | |||||||||
Warranty | N/A 3 yr | |||||||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||||
Application |
N/A
|
|||||||||
Additional Information |
N/A
|
|||||||||
Digital Indicators | N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. | |||||||||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|||||||||
|