Type |
N/A Transmitter |
Connection Type |
N/A Male National Pipe Thread (MNPT) |
Seal Material |
N/A 316 Stainless Steel |
Low Calibrated Temperature Range |
N/A -22 ºF |
High Calibrated Temperature Range |
N/A 302 ºF |
Housing Material |
N/A 316 Stainless Steel |
Connection Size |
N/A 1/4 in |
Output Signal |
N/A 4 to 20 mA, 2-Wire |
Electrical Connection |
N/A M12 x 1 (4-pin) |
Power Supply |
N/A 10 to 30 Vdc |
Accuracy |
N/A
±0.80 ºF (± 0.45 ºC) Maximum uncertainty calculated @ maximum span, maximum measurement temperature, and ambient temperature. Maximum uncertainty includes Usensing element, Usensor measurement, Uoutput linearization. |
Storage Temperature [Max] |
N/A 85 ºC185 ºF |
Storage Temperature [Min] |
N/A -40 ºC-40 ºF |
Series |
N/A 810 |
Standard Temperature Ranges |
N/A -22 to 302 ºF |
Sensor Protection |
N/A Burnout Protected from 3.3 to 23 mA |
Measuring Element |
N/A PT1000 Class A |
Load Limitations |
N/A ≤(Supply Voltage - 10 Volts)/0.023 A |
Pressure Rating |
N/A 3,915 psi |
Ambient Temperature Range |
N/A -40 to 185 ºF-40 to 85 ºC |
Environmental Protection |
N/A Ingress Protection (IP67) |
Electrical Protection |
N/A Reverse polarity, over-voltage and short circuit protection |
Warranty |
N/A 3 yr |
Measuring Element Accuracy |
N/A PT1000 Class A |
Temperature Sensor Accuracy |
N/A
For ºF: ±[1.8*(0.15 + 0.002 (t - 32) / 1.8)] For ºC: ±(0.15 K + 0.002 I t I) per EN 60751 |
Sensor Diameter |
N/A 6 mm |
Sensor Length |
N/A 1 in |
Industry Standards/Certifications |
N/A
European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) per EN 61326 Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |