Type |
N/A Probe with Connection Head |
Series |
N/A 915 |
Connection Type |
N/A Male National Pipe Thread (MNPT) |
Wetted Materials |
N/A 316 Stainless Steel |
Lead Wires |
N/A Stranded 22 AWG standard, Polyvinyl Chloride (PVC) or Polytetrafluoroethylene (PTFE) Insulation |
Temperature Ranges [Min] |
N/A -50 ºF |
Temperature Ranges [Max] |
N/A 400 ºF |
Connection Size |
N/A 1/2 in |
Accuracy |
N/A ±0.06% (±0.15 ºC) at 0 ºC, Class A |
Element Types |
N/A PT100 Ω at 0 ºC |
Circuit Types |
N/A Single, 3-Wire |
Electrical Connection |
N/A Connection Head with 1/2 " National Pipe Thread (NPT) Conduit |
Electrical Connection Materials |
N/A Polypropylene (PP), White |
Standard Finish [Max] |
N/A 32 µin |
Pressure Ratings for Tube |
N/A 500 psi34.5 bar |
Resistance Temperature Device (RTD) Element |
N/A PT100 Ω at 32 ºF (0 ºC), α=0.00385 International Electrotechnical Commission (IEC 751) |
Self-Heating |
N/A 50 mW / ºC Typical in Moving Water |
Insulation Resistance |
N/A
Single Element Probes: 100 mega Ω/m" at 500 Vdc, Leads to Case Dual Element Probes: 100 mega Ω/m" at 100 Vdc, Between Element and Leads to Case |
Transition |
N/A Sheath to Wire Transition Maximum Temperature 266 ºF (130 ºC) |
Optional Transmitter/Output |
N/A 4 to 20 mA, 2-Wire, Upscale Burnout |
Environmental Protection |
N/A
A1/A2:National Electrical Manufacturers Association (NEMA) 4 P1 & S1/S2:National Electrical Manufacturers Association (NEMA) 4X |
Warranty |
N/A 3 yr |
Stem Diameters |
N/A 1/4 in |
Stem Lengths |
N/A 9 in |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Additional Information |
N/A
|
Resistance Temperature Device (RTD) Connection Head |
N/A
|
Resistance Temperature Device (RTD) Terminal Block |
N/A
|
Resistance Temperature Device (RTD) Transmitter |
N/A NOSHOK's Probe Type Industrial RTD is available with a variety of fitting sizes and probe diameters. |
Thermowells |
N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |