Type |
N/A Diaphragm Seal |
Style |
N/A Non-Replaceable Diaphragm Seal |
Instrument Connection Size |
N/A 1/4 in |
Process Connection |
N/A National Pipe Thread (NPT) |
Upper Housing Material |
N/A 316 Stainless Steel |
Diaphragm Material |
N/A 316 Stainless Steel |
Process Connection Size |
N/A 1 in |
Flushing Connection Size |
N/A 1/4 in |
Flushing Connection Type |
N/A National Pipe Thread (NPT) |
Seal Type |
N/A Threaded with welded diaphragm |
Lower Housing Connection Size |
N/A 1/4 in1/2 in3/4 in1 in |
Lower Housing Connection Type |
N/A National Pipe Thread (NPT) |
Lower Housing Flushing Port |
N/A Optional 1/8" NPT and 1/4" NPT |
Upper Housing Type |
N/A Continuous Duty |
Diaphragm Size |
N/A 2.1 in |
Diaphragm Displacement |
N/A 1.5 mL |
Instrument Connection Type |
N/A National Pipe Thread (NPT) |
Warranty |
N/A 1 yr |
Stock |
N/A Yes |
Instrument Type |
N/A Gauges, Transducers, Switches |
Pressure [Min] for Gauges 2-1/2 to 4-1/2 in. Size |
N/A 0 to 30 psig |
Pressure [Min] for Transducers |
N/A 0 to 30 psig |
Pressure [Min] for Switches |
N/A 0 to 30 psig |
Pressure [Max] for Gauges 2-1/2 to 4-1/2 in. Size |
N/A 0 to 2,500 psig |
Pressure [Max] for Transducers |
N/A 0 to 2,500 psig |
Pressure [Max] for Switches |
N/A 0 to 2,500 psig |
O-Ring Temperature Limits for Nitrile Butadiene Rubber (NBR) Material |
N/A -40 to 250 ºF |
O-Ring Temperature Limits for Polytetrafluoroethylene (PTFE) Material |
N/A -400 to 400 ºF |
O-Ring Temperature Limits for Fluorocarbon (FKM) Material |
N/A -10 to 400 ºF |
Diaphragm Pressure Limits for Polytetrafluoroethylene (PTFE) Material |
N/A 2,000 psi |
Diaphragm Pressure Limits for Fluorocarbon (FKM) Material |
N/A 2,000 psi |
Diaphragm Temperature Limits for Polytetrafluoroethylene (PTFE) Material |
N/A -40 to 400 ºF |
Diaphragm Temperature Limits for Fluorocarbon (FKM) Material |
N/A -10 to 400 ºF |
Note for Diaphragm Pressure and Temperature Limits |
N/A Metallic diaphragms determined by pressure range of seal type, restricted to temperature range of fill fluid. |
Maximum Temperature Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material |
N/A 180 ºF |
Maximum Pressure Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material |
N/A 200 psi |
Maximum Pressure Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material |
N/A 200 psi |
Maximum Pressure Limits for Polyvinyl Chloride (PVC) Bottom Housing Material |
N/A 80 psi125 psi200 psi |
Maximum Pressure Limits for Polypropylene (PP) Bottom Housing Material |
N/A 200 psi |
Maximum Temperature Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material |
N/A 150 ºF |
Maximum Temperature Limits for Polyvinyl Chloride (PVC) Bottom Housing Material |
N/A 74 ºF125 ºF150 ºF |
Maximum Temperature Limits for Polypropylene (PP) Bottom Housing Material |
N/A 140 ºF |
Note for Maximum Pressure and Temperature Limits Bottom Housing Material |
N/A Metallic lower housings determined by pressure range of seal type, restricted to temperature range of fill fluid. |
Application |
N/A
|
Additional Information |
N/A
|
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. Gauge failures determined to be caused by over-range, incompatibility with environment or product media and abuse will not be considered under this warranty. NOSHOK, Inc. will, at its discretion, repair or replace the working parts of the damaged gauge without cost to the customer. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Cooling Elements |
N/A
|
Diaphragm Seal Fill Options |
N/A
|
Distribution Manifolds |
N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. |
Plain and Armored Capillaries |
N/A
|