Type |
N/A Bimetal Thermometer |
Series |
N/A 100 |
Case and Bezel Material |
N/A 304 Stainless Steel |
Full Scale Accuracy (±) |
N/A 1.0 % |
Accuracy Grade |
N/A A |
Accuracy Standard |
N/A American Society of Mechanical Engineers (ASME) B40.3 |
Connection Size |
N/A 1/4 in |
Lens |
N/A Instrument Glass |
Dial Size |
N/A 2 in |
Case Type |
N/A Back Connection |
Temperature Scale |
N/A Single |
Connection Type |
N/A National Pipe Thread (NPT) |
Pointer |
N/A Aluminum, Black Finished |
Dial |
N/A Anodized Aluminum with large black numbers and graduations |
Wetted Parts Material |
N/A 304 Stainless Steel |
Optional Wetted Parts Material |
N/A 316 Stainless Steel |
Optional Case and Bezel Material |
N/A 316 Stainless Steel |
Hermetic Seal |
N/A Per American Society of Mechanical Engineers (ASME) B40.3 dustproof and leakproof |
Bimetal Coil |
N/A Silicone coated helix coil on ranges below 500 ºF for vibration dampening, maximum heat transfer and response time |
Warranty |
N/A 1 yr |
Limits Over Temperature at 100 Percentage |
N/A Up to 250 ºF |
Limits Over Temperature at 50 Percentage |
N/A 250 to 500 ºF |
Limits Over Temperature at Continuous Use Up to 800 ºF |
N/A 550 to 1,000 ºF |
Limits Over Temperature at Intermittent Use Over 800 ºF |
N/A 550 to 1,000 ºF |
Stem Lengths |
N/A 2-1/2 in |
Stem Diameter |
N/A 0.250 in6.35 mm |
Stock |
N/A Yes |
Application |
N/A
|
Options and Accessories |
N/A
|
100 Series Bimetal Thermometer Silicone Filled (SL) |
N/A
|
Mounting Flanges - Bimetal Thermometers |
N/A Various sizes and types of mounting flanges are available |
Special Dials - Bimetal Thermometers |
N/A Special ranges and dials with company names, company logos, part numbers, telephone numbers, or almost any custom layout is available |
Certified Calibration |
N/A
|
Stem Types |
N/A
|
Thermowells |
N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |