Print Back
  • Adjustable pressure ranges vacuum to 1,160 psig
  • All ranges are user adjustable from vacuum to full scale with standard on board display
  • 4 mA to 20 mA HART® optional pressure transmitter
  • Accuracy ±0.2% of adjusted span
  • 4:1 turn down
  • All Stainless Steel construction with 316 Stainless Steel wetted parts
  • Built to suppress RFI, EMI and ESD
PTI20 PMC Photograph
Unit of Measure
« 26 27 28 29 

Part Number

Pressure Range

Accuracy

Output Signal

Process Connection

Electrical Connection

Description

PTI20-1150psig-1-1-79-28-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1" flush PMC N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1" flush PMC, 1/2" National Pipe Thread (NPT) female, transparent cover
PTI20-1150psig-1-1-79-71 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1" flush PMC N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1" flush PMC, PG9 cable gland
PTI20-1150psig-1-1-79-71-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1" flush PMC N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1" flush PMC, PG9 cable gland, transparent cover
PTI20-1150psig-1-1-80-25 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, M12 x 1 4 pin
PTI20-1150psig-1-1-80-25-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, M12 x 1 4 pin, transparent cover
PTI20-1150psig-1-1-80-28 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, 1/2" National Pipe Thread (NPT) female
PTI20-1150psig-1-1-80-28-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, 1/2" National Pipe Thread (NPT) female, transparent cover
PTI20-1150psig-1-1-80-71 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, PG9 cable gland
PTI20-1150psig-1-1-80-71-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire N/A 1-1/2" in flush PMC N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 1-1/2" flush PMC, PG9 cable gland, transparent cover
PTI20-1150psig-1-43-8-25 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, M12 x 1 4 pin
PTI20-1150psig-1-43-8-25-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, M12 x 1 4 pin, transparent cover
PTI20-1150psig-1-43-8-28 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, 1/2" National Pipe Thread (NPT) female
PTI20-1150psig-1-43-8-28-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, 1/2" National Pipe Thread (NPT) female, transparent cover
PTI20-1150psig-1-43-8-71 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, PG9 cable gland
PTI20-1150psig-1-43-8-71-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) male N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) male, PG9 cable gland, transparent cover
PTI20-1150psig-1-43-69-25 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, M12 x 1 4 pin
PTI20-1150psig-1-43-69-25-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, M12 x 1 4 pin, transparent cover
PTI20-1150psig-1-43-69-28 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, 1/2" National Pipe Thread (NPT) female
PTI20-1150psig-1-43-69-28-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, 1/2" National Pipe Thread (NPT) female, transparent cover
PTI20-1150psig-1-43-69-71 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, PG9 cable gland
PTI20-1150psig-1-43-69-71-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1/2" National Pipe Thread (NPT) female N/A PG9 Cable Gland N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1/2" National Pipe Thread (NPT) female, PG9 cable gland, transparent cover
PTI20-1150psig-1-43-73-25 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1" National Pipe Thread (NPT) male flush N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1" National Pipe Thread (NPT) male flush, M12 x 1 4 pin
PTI20-1150psig-1-43-73-25-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1" National Pipe Thread (NPT) male flush N/A M12 x 1 4 pin N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1" National Pipe Thread (NPT) male flush, M12 x 1 4 pin, transparent cover
PTI20-1150psig-1-43-73-28 N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1" National Pipe Thread (NPT) male flush N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1" National Pipe Thread (NPT) male flush, 1/2" National Pipe Thread (NPT) female
PTI20-1150psig-1-43-73-28-TC N/A Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) N/A ±0.2% of adjusted span with 4:1 turn down N/A 4 mA to 20 mA, 2-wire with HART® N/A 1" National Pipe Thread (NPT) male flush N/A 1/2" National Pipe Thread (NPT) female N/A Intelligent Pressure Transmitter, Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire with HART®, 1" National Pipe Thread (NPT) male flush, 1/2" National Pipe Thread (NPT) female, transparent cover
Unit of Measure
« 26 27 28 29