About
- High accuracy 4 mA to 20 mA loop-powered indicators for NOSHOK 11 Series Sanitary, 300, 615/616 Series pressure transmitters and 800 Series temperature transmitters
- Can be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN 175301-803 Form A connector
- Easily inserted between the transmitter body and the connector
- Programmable to display a range of -1999 to 9999; may be tilted for better viewing
Featured Specifications
Series
1800
Storage Temperature
-4 to 153 ºF|-20 to 70 ºC
Drop Direct Current (DC) Voltage
≤ 2 V
Non-Condensing Humidity
<90 %
Product Specifications|Additional Information|Options and Accessories|Note|Applications|Limitations Which Apply Are
Product Specifications
▲| Type | Digital Indicator |
| Series | 1800 |
| Process Display | 4 digit, 0.4" liquid crystal display (-1999 to 9999) |
| Input Signals | 4 to 20 mA |
| Accuracy | <0.2 |
| Digit Accuracy (±) | 1 % |
| Storage Temperature ºF | -4 to 153 ºF |
| Storage Temperature ºC | -20 to 70 ºC |
| Effect | ≤ 0.1% of Full Scale/18 ºF (10 ºC) |
| Full Scale Temperature ºF | 18 ºF |
| Full Scale Temperature ºC | 10 ºC |
| Environmental Rating | IP65 per EN60529 |
| Input Signals Current | 4 to 20 mA |
| Optional Direct Current (DC) Voltage | 0 to 10 V |
| Key Pad | 3 programmable function keys for relay option only, located behind the face plate |
| Power Requirement | Loop powered by sensors excitation |
| Drop Direct Current (DC) Voltage | ≤ 2 V |
| Electrical Connection | DIN 175301-803 Form A |
| Memory | Electrically Erasable Programmable Read-Only Memory (EEPROM) |
| Non-Condensing Humidity | <90 % |
| Update Rate | 200 ms |
| Selectable Filtering | 0.2 to 1.5 s |
| Relay Option | 1 Transistor, N-Switching |
| Linearization | 2 Point |
| Electromagnetic Rating | European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326-1, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Weight | 3 oz |
| Warranty | 1 yr |
| Options | No Options |
Additional Information
▲| Additional Information |
|
Options and Accessories
▲| Installed Options and Accessories | Optional Relay - 1 x NPN Switch (1) |
Note
▲| Note | Indicate display range or order eg. 0-1,000 for 4 mA to 20 mA. |
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |