Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Pressure Range |
N/A -15 psig to 15 psig |
Accuracy |
N/A ±0.5% Full Scale |
Operating Temperature [Min] |
N/A -10 ºC14 ºF |
Operating Temperature [Max] |
N/A 50 ºC122 ºF |
Media Temperature [Min] |
N/A -20 ºC-4 ºF |
Media Temperature [Max] |
N/A 50 ºC122 ºF |
Storage Temperature [Min] |
N/A -18 ºC0 ºF |
Storage Temperature [Max] |
N/A 55 ºC130 ºF |
Measuring Element |
N/A 316L Stainless Steel |
Process Connection |
N/A 1/4" NPT Male |
Case |
N/A PBT with 30% glass fiber |
Display |
N/A Back-lighting: activated via button Bar graph: 0 to 100% in 5% steps Resolution: 4 1/2 digits |
Power requirement |
N/A 3 x 1.5 V AA Alkaline batteries Typically > 4,000 hours |
Response time |
N/A 200 ms |
Proof Pressure |
N/A > 7.500 psi: 1.43 times full scale ≤ 70psi: 3 times full scale ≥ 100 to 7,500 psi: 2 times full scale |
Burst pressure |
N/A >7.500 psi: 2 times full scale ≤ 70psi: 4 times full scale ≥ 100 to 7,500 psi: 3 times full scale |
Programmable functions, Measuring units |
N/A Adjustable through front key pad psi, bar, mbar, MPa, kg/cm2 and 1 user defined unit |
Environmental rating |
N/A IP65 |
Accessories / Uninstalled Options |
N/A PGE20-GC1 - Guage Carrying Case (1 gauge) PGE20-GC3 - Guage Carrying Case (3 gauge) PGE20-IC - Interface cable (Micro USB to USB cable 2m) |
Weight |
N/A 0.77 lb |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|