• High visibility tank level display
  • Individually calibrated indicator scale
  • Electronic (4 mA to 20 mA) or pneumatic input
  • Direct replacement for manometer gauges
Unit of Measure

Specifications

Type

N/A LevelBAR Electronic Column Indicator

Series

N/A 5111

Environmental Operating Temperature [Min]

N/A -1 ºC30 ºF

Environmental Operating Temperature [Max]

N/A 49 ºC120 ºF

Full Scale Output (FSO) Direct Current

N/A 4 to 20 mA

Physical Data

N/A 304 Stainless Steel housing and cover with gasket seal, transparent polycarbonate display window. Intended to meet splash proof requirements. The use of waterproof conduit hubs or fittings may be required during installation. Not rated for continuous explosion hazard areas.

Frequency [Max]

N/A 60 Hz

Frequency [Min]

N/A 50 Hz

Display Length

N/A 10 in254 mm

Power Output

N/A 24 V

Nominal Pressure (Min)

N/A 0 psid

Display Accuracy/Resolution

N/A 1 %

Alternating Current (AC) Voltage

N/A 100 to 240 V

Display Type

N/A 100-Segment Light Emitting Diode (LED)

Input

N/A mA Input: 4-12 mAdc through 4-20 mAdc

Nominal Input Impedance (Resistance)

N/A 150 O

Overload Current Limiting

N/A Automatic trip/reset circuit using PTC (positive temperature coefficient) resistor holds maximum current level within operating range of internal components.

Signal Input (Electronic Input Model)

N/A 4 to 12 mA DC (Minimum) to 4 to 20 mA DC Full Scale Range

Application

Application

N/A
  • Tank level Indication
  • Marine
    • Tank Level, Draft Monitoring and Vessel Management
    • Ballast Water
    • Fuel Oil
    • Fresh Water
    • Lube Oil
    • Brine
    • Preload
    • Holding

Options and Accessories

Replacement Fuses/Terminal Connectors

N/A 7469-21-0: 500 mA 250 V Fast Acting (AGC) Fuse, 0.25 x 1.25 in, Replacement 5-Pack

5858-2: 2-Terminal Connector

5858-3: 3-Terminal Socket Connector

Scale Ordering Information

N/A A standard 1-unit scale is included in the package price listed for LevelBAR models. The LevelBAR scale is custom marked in any specified unit of measurement (gallons, liters, barrels, etc.). An optional 2-unit scale can combine any two different measurements such as weight and volume, or volume and depth.

When ordering, the following information must be supplied. If replacing an existing scale, also provide the original serial number.
  • Specific Gravity (Density) of Tank Contents
  • Product Designation (tank contents)
  • Description of Tank (e.g., Walker 6000 gal silo)
  • Tank Dimensions
  • Tank Name (to be noted on scale)
  • Pressure Range of transmitter or LevelBAR
  • Scaling Units (e.g., lbs, gals, liters, etc.)
Scales are calculated for the individual tank geometry and product specific gravity. Scaling adjustments setting (REF HIGH) is noted on the side of the scale. This is used to set the full scale display based on pressure range of the transmitter and maximum pressure created by depth of tank product.

Tank Calibrations - The LevelBAR indicator should not be used for physical water calibrations of tanks. Use of a pressure standard or other high accuracy pressure measurement instrument is recommended.

Replacement Scales

N/A 5980-11: Replacement 1-Unit LevelBAR Scale Assembly

5980-21: Replacement 2-Unit LevelBAR Scale Assembly

Features

LevelBAR Custom Scale

N/A Scales are calculated for the individual tank geometry and product specific gravity permitting the LevelBAR system to be used for almost any kind and shape of tank, including horizontal cylindrical storage tanks. Custom marked in any specified unit of measurement (gallons, liters, pounds, etc.), it may also be ordered with an optional 2-unit scale that combines any two different measurements of weight, volume, or depth. Factory calibration allows full scale ranging of the display when maximum input is less than 20 mA to eliminate field span adjustment of the level transmitter.

4 to 20 mA LevelBAR Electronic Input

N/A Electronic - 4 - 20 mA signal from Sensor or Electronic Transmitter is transmitted to LevelBAR (electronic input).

Local or remote indication of tank inventory is provided by the LevelBAR column display. At the tank, a level transmitter (such as the KING-GAGE® ES2) provides a standard 4-20 mA signal which is proportional to the hydrostatic pressure created by liquid depth. 100-240 Vac 50/60 Hz power is required at the LevelBAR indicator which also provides power to the transmitter over the two wire signal loop circuit.
  • Bright graphic display of level
  • LED column viewable in direct sunlight
  • Backlit scale for nighttime viewing
  • Signal fault diagnostic alert

LevelBAR Indicator

N/A Electronic input (4-20 mA two wire)

The electronic input version accepts a standard 4–20 mAdc signal from typical two wire pressure transmitters. These models include watertight cord grip (strain relief) connectors, factory calibration, and custom marked scale.

Dependable Operation

Dependable Operation

N/A LevelBAR is simple to install and maintain. There are no extensive adjustments or calculations to perform. Its rugged stainless steel enclosure suits any environment. The unit presents a highly visible graphic display for control room or process floor, whether there be subdued light conditions or even bright sunlight. Simply connect power and signal input to make the system operational. (The use of waterproof conduit hubs or fittings may be required during installation. Not rated for continuous explosion hazard areas. Compressed air source is required for Purge Control transmitters.)

Additional Information

Additional Information

N/A
  • High Visibility Tank Level Display
  • Individually Calibrated Indicator Scale
  • Electronic (4-20 mA) or Pneumatic Input
  • Direct Replacement for Manometer Gauges
The KING-GAGE® LevelBAR (v2) delivers a bright multi-segment LED column to graphically indicate tank level. The system monitors tank level by reading the proportional 4-20 mA signal output from compatible two wire level transmitters. The available D/P option alternatively accommodates direct pneumatic pressure measurement.

The multi-segment LED column provides graphic indication of tank levels for operations personnel. Rugged stainless steel housing resists corrosion affording protection for the internal electronics and is intended to meet splash proof requirements. A backlighting feature makes the scale readable in the absence of ambient illumination while the red LED column is viewable even in bright daylight.

LevelBAR indicators can be used singly or in multiples to provide additional display locations simply by extending the signal loop circuit. This tank level display takes the guesswork out of installation and troubleshooting with practical elements such as loop circuit status (on/off/open) and fault (short) indicators. With the available differential pressure (D/P) option, the LevelBAR indicator can be used as a direct replacement for mercury tank gauges or other fluid-filled manometers.

Warnings

Product Warranty

N/A All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase.

Repair Services Warranty: 90 days limited warranty.

Prop 65 Warnings

N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Note

Note

N/A Scale information must be supplied when order is placed.