  • Ranges from 0 inH2O to 50 inH2O through 0 psig to 1,000 psig
  • Current and voltage outputs available
  • 316 Stainless Steel, Polyamide and Polyurethane wetted parts
Unit of Measure

Specifications

Type

N/A Submersible Level Transmitter

Series

N/A 612

Pressure Range

N/A 0 to 100 psig230.8 ftH2O

Full Scale Best Fit Straight Line (BFSL) Accuracy (±)

N/A 0.25 %

Note for Accuracy

N/A Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors.

Output Signal

N/A 4 mA to 20 mA, 2-wire

Process Connections

N/A G 1/2 B x 1/2 in. Male National Pipe Thread (MNPT) with 1/4 in. Female National Pipe Thread (FNPT)

Electrical Connection

N/A Standard Polyurethane (PUR) Cable

Style

N/A Level Transmitter

Storage Temperature [Min]

N/A -30 ºC-22 ºF

Storage Temperature [Max]

N/A 80 ºC175 ºF

Stability

N/A ≤ ± 0.2% full scale for 1 year, non-accumulating

Response Time

N/A ≤1 ms

Service Life

N/A < 100,000,000 load cycles

Power Requirement

N/A 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire)
5 Vdc to 30 Vdc (0.5 Vdc to 2.5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)

Load Limitations

N/A ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire

Proof Pressure

N/A 2 Times Range

Burst Pressure

N/A 4 Times Range

Measuring Element

N/A Cap: Polyamide, 316 stainless steel with weighted Nose Cone
Cable: Polyurethane, optional FEP or PVC with double water block

Connection Material

N/A 316 Stainless Steel

Housing Material

N/A 316 Stainless Steel

Environmental Rating

N/A Ingress Protection (IP68)

Electromagnetic Rating

N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection

Electrical Protection

N/A Reverse polarity protection, short circuit and optional lightning protection per European Standards (EN) 6100-4-5; 1.5J

Shock According to International Electrotechnical Commission (IEC) 60068-2-27

N/A 100 g

Vibration According to International Electrotechnical Commission (IEC) 60068-2-6

N/A 15 g

Approximate Weight

N/A 7 oz

Warranty

N/A 3 yr

Cable Length

N/A 25 ft

Related Items

N/A , Submersible Cable Clamp
, Submersible Filter Element

Temperature Ranges

Compensated Temperature Range

N/A 32 to 122 ºF0 to 50 ºC

Note for Compensated Temperature Range

N/A Effect ± 0.01%/ºF for zero and span

Media Temperature Range

N/A 14 to 122 ºF-10 to 50 ºC

Prop 65 Warnings

Prop 65 Warnings

N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Options and Accessories

Options and Accessories

N/A
  • Cable Clamp (CBC)
  • Cable Junction Box (NEMA 4X) (JB)
  • Desiccant Cartridge (DC)
  • Filter Element (FE)
  • Lightning Protection (LP) (Only available with PUR cable)
  • PT100 RTD1 (PT1) (Only available with PUR cable)

Limitations Which Apply Are

Limitations Which Apply Are

N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Application

Application

N/A
  • Irrigation
  • Tank monitoring
  • Water & wastewater
  • Well head measurement

Additional Information

Additional Information

N/A
  • CE compliant to suppress RFI, EMI and ESD
  • Ideal for applications including irrigation, tank monitoring, water & wastewater and well head measurement