MENU
NOSHOK'S COVID-19 Response
  • 1-1/2" and 2" clamp, fillable dry or liquid-filled gauge
  • Electropolished Stainless Steel case
  • 316 Stainless Steel wetted parts
  • 3A Certified
  • C.I.P, S.I.P and Autoclave (only dry gauges are recommended for Autoclave)
Unit of Measure

Specifications

Type

Pressure Gauge

Series

10 Series Heavy-Duty, Bottom Connected

Case Material

Electropolished 304 Stainless Steel

Operating Temperature [Min]

-4 ºC25 ºF

Operating Temperature [Max]

60 ºC140 ºF

Full Scale Accuracy (±)

1.6 %

Lens

Safety Glass

Connection

1-1/2 or 2 in. ASME-BPE Sanitary Clamp, 316L stainless steel, Diaphragm 316L stainless steel, electropolished to 32 μin Ra or better

Dial

Aluminum, white background with black scale.

Bayonet Ring Material

Electropolished 304 Stainless Steel

Clamp Size

1-1/2 in

Gauge Size

2-1/2 in

Seal Fill Fluid

Glycerin

Pressure Range

0 to 160 psig

Media Temperature Range

-40 to 300 ºF-40 to 150 ºC

Ambient Temperature Range

25 to 140 ºF-4 to 60 ºC

Gauge Fill Fluids

Glycerin

Measuring Element

316 Stainless Steel "C" Tube

Pointer

Balanced Aluminum, Black Finish

Movement

Stainless Steel

Fill Liquid

Glycerin, USP Grade

Warranty

1 yr

Options

None

Stock

Yes

Unit Net Weight

1.23 lb

Options and Accessories

Options and Accessories

Polycarbonate Lens (3), None

10 Series Heavy-Duty Sanitary Pressure Gauges

  • None (0)
  • Maximum Indicating Pointer - 4" Gauge (1)
  • Adjustable Pointer - 4" Gauge (2)
  • Polycarbonate Lens - 2-1/2" Gauge (3)
  • Polycarbonate Lens - 4" Gauge (3)

Sanitary Clamps and Gaskets

  • Clamp-style fittings are constructed of T304 Stainless Steel; T316 Stainless Steel on request
  • Double hinge design for easy installation and removal
  • Available in sizes from 3/4" to 4"
  • Standard pressure rating of 500 psi at 70 ºF (21 ºC); up to 3000 psi rating on request
  • Clamp gaskets are available in NBR, EPDM, PTFE and FKM
  • All clamps and gaskets meet FDA and 3A sanitary standards
ASME-BPE Sanitary Clamp
1-1/2" (CR 12)
2" (CR 16)
2-1/2" (CR 20)
3" (CR 24)

NBR Gasket
1-1/2" (BG 12)
2" (BG 16)
2-1/2" (BG 20)
3" (BG 24)

PTFE Gasket
1-1/2" (TG 12)
2" (TG 16)
2-1/2" (TG 20)
3" (TG 24)

Application

Application

  • Food & beverage processing
  • Pasteurization systems
  • Pharmaceutical
  • Medical

Prop 65 Warnings

Prop 65 Warnings

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer.  For more information go to www.P65Warnings.ca.gov

Caution

Caution

Operating conditions including, but not limited to, system pressure, media compatibility and ambient conditions must be considered when selecting gauges and accessories. Improper selections and use of gauges could possibly cause gauge failure and lead to possible property damage or personal injury. Refer to the American National Standard ANSI B40.1 for the correct selection and use of gauges. A copy of this standard may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2

Diaphragm seal must be installed facing downward or in a vertical position for drain ability.

Do not install diaphragm seal facing in an upward position.

Limitations Which Apply Are

Limitations Which Apply Are

  • Bourdon tube pressure gauges must be used within their calibrated maximum range to prevent damage
  • The pressure gauges must be operated within the following working pressure limits:
    • Dynamic Pressure application, 60% of the dial range
    • Static Pressure applications, where no sharp fluctuations occur, 90% of the dial range
  • The gauges must be operated within specified ambient temperature ranges
  • Determination of gauge failures will be made by NOSHOK, Inc., which will use its equipment and personnel or a certified test facility specializing in this type of evaluation and determination. Gauge failures determined to be caused by over-range, incompatibility with environment or product media and abuse will not be considered under this warranty. NOSHOK, Inc. will, at its discretion, repair or replace the working parts of the damaged gauge without cost to the customer. This written warranty applies only to the NOSHOK gauges referenced in the first paragraph of this warranty, sold by NOSHOK, Inc. and its authorized distributors.

Note

Note

Autoclave requires the addition of optional laminated safety glass lens