Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Pressure Gauge |
Series |
N/A 10 Series Heavy-Duty, Bottom Connected |
Case Material |
N/A Electropolished 304 Stainless Steel |
Operating Temperature [Min] |
N/A -4 ºC25 ºF |
Operating Temperature [Max] |
N/A 60 ºC140 ºF |
Full Scale Accuracy (±) |
N/A 1.6 % |
Lens |
N/A Safety Glass |
Connection |
N/A 1-1/2 or 2 in. ASME-BPE Sanitary Clamp, 316L stainless steel, Diaphragm 316L stainless steel, electropolished to 32 μin Ra or better |
Dial |
N/A Aluminum, white background with black scale. |
Bayonet Ring Material |
N/A Electropolished 304 Stainless Steel |
Clamp Size |
N/A 2 in |
Gauge Size |
N/A 2-1/2 in |
Seal Fill Fluid |
N/A Glycerin |
Pressure Range |
N/A 0 to 600 psig |
Media Temperature Range |
N/A -40 to 300 ºF-40 to 150 ºC |
Ambient Temperature Range |
N/A 25 to 140 ºF-4 to 60 ºC |
Gauge Fill Fluids |
N/A None |
Measuring Element |
N/A 316 Stainless Steel "C" Tube |
Pointer |
N/A Balanced Aluminum, Black Finish |
Movement |
N/A Stainless Steel |
Fill Liquid |
N/A Glycerin, USP Grade |
Warranty |
N/A 1 yr |
Options |
N/A None |
Unit Net Weight |
N/A 1.23 lb |
Options and Accessories |
N/A Polycarbonate Lens (3), None |
10 Series Heavy-Duty Sanitary Pressure Gauges |
N/A
|
Sanitary Clamps and Gaskets |
N/A
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
|
Caution |
N/A
Operating conditions including, but not limited to, system pressure, media compatibility and ambient conditions must be considered when selecting gauges and accessories. Improper selections and use of gauges could possibly cause gauge failure and lead to possible property damage or personal injury. Refer to the American National Standard ANSI B40.1 for the correct selection and use of gauges. A copy of this standard may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2 Diaphragm seal must be installed facing downward or in a vertical position for drain ability. Do not install diaphragm seal facing in an upward position. |
Limitations Which Apply Are |
N/A
|