About
- Block valve and stabilized tap are joined by a coupling nut which allows easy installation and non-rotation of the valve
- Slotted bolt holes allow for 2-1/8" and 2-1/4" bolt spacings
- Designed to reinforce the entire installation by shifting radial-stress load away from the NPT connections
- 0.375" bore for unrestricted passage of process gas
- Patent pending
Featured Specifications
Material
Steel
Documents
Product Specifications|Additional Information|Options and Accessories|Limitations Which Apply Are|Prop 65 Warnings
Product Specifications
▲| Connection | 1/2" NPT, Flange |
| Weight | 10.6 lb |
| Material | Steel |
| Orifice Size | 0.375 in |
| Flow Coefficient Cv | 3 |
| Series | SV |
| Connector Type | Stabilized connector pair with integral valve (For flat installations, orifice fitting) |
| Pressure Rating at 200 Degree Fahrenheit (ºF) Temperature_psi | 6,000 psi |
| Stem Seal and Type | All 316 Stainless Steel stems with FKM o-ring and PTFE back-up ring below the threads |
| Warranty | 3 yr |
| Bolt Material | Carbon Steel |
| Related Items | VHS, 316 Stainless Steel Vertical to Horizontal Manifold Adapter |
Additional Information
▲| Additional Information |
|
Options and Accessories
▲| Installed Options and Accessories | Low temperature FKM o-ring (VT3) |
| Dielectric Kits DK Series | Dielectric Kits are designed to maintain the integrity and reliability of the pipeline and piping system through safety and corrosion protection. Dielectric Kits provide a non-conductive barrier between the process piping and the instrument and isolate components from the effects of electrical current. By eliminating metal-to-metal contact, current is halted to prevent corrosion and aid in the cathodic protection of the system.
|
| Direct Connect Assembly for Oil and Gas Applications | The NOSHOK Direct Connect Assembly provides an installation that keeps the meter close to the orifice taps for accurate flow measurements. |
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |