About
Sanitary Transmitter, 1-1/2" Sanitary Clamp, ±0.25% Accuracy (BFSL), 0 psig to 300 psig, 4 mA to 20 mA Output, M12 x 1 (4-Pin)
Featured Specifications
Pressure Range
0 to 300 psig
Accuracy
±0.25% full scale (BFSL)
Electrical Connection
M12 x 1 (4-Pin)
Clamp Size
1-1/2 in
Assets
Product Specifications
▲| Product Series | 11 |
| Clamp Size | 1-1/2 in |
| Approximate Weight | 1.1 lb |
| Storage Temperature (Min.) | -40 ºF
-40 ºC |
| Storage Temperature (Max.) | 212 ºF
100 ºC |
| Housing Material | 316 Stainless Steel |
| Accuracy | ±0.25% full scale (BFSL) |
| Output Signal | 4 mA to 20 mA, 2-wire |
| Electrical Connection | M12 x 1 (4-Pin) |
| Environmental Rating | Ingress Protection (IP65) |
| Connection Material | 316 Stainless Steel |
| Seal Fill Fluid | FFL77 White Oil |
| Pressure Range | 0 to 300 psig |
| Stability | ±0.2% full scale for 1 year, non-accumulating |
| Adjustment | ±10% full scale for zero and span |
| Response Time | ≤10 ms |
| Service Life | > 100,000,000 Load Cycles |
| Power Requirement | 10 Vdc to 30 Vdc |
| Current for 4 to 20 Milliampere (mA) | 0.02 A |
| Measuring Element | 316 Stainless Steel |
| Electrical Protection | Reverse polarity, over-voltage and short circuit protection |
| Electromagnetic Rating | European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | 1,000 g |
| Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | 15 g |
| Warranty | 3 yr |
Temperature Ranges
▲| Compensated Temperature Range | 32 to 176 ºF
0 to 80 ºC |
| Note for Compensated Temperature Range | Effect ±0.01%/ºF for zero and span |
| Media Temperature Range | -40 to 300 ºF
-40 to 150 ºC |
| Ambient Temperature Range | -40 to 176 ºF
-40 to 80 ºC |
| Options and Accessories |
|
| Digital Indicators | NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
| Sanitary Clamps and Gaskets |
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
| Applications |
|
| Caution | NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2. Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position. |
| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Applications
▲| Application |
|