About
Small Diameter Submersible Transmitter, Wetted Materials: 316 SS, 0 psig to 25 psig, ±1% of Span Accuracy, 4 mA to 20 mA Output + HART, Polyamide Nose Cone, 150 ft PUR Cable, Cable Clamp
Featured Specifications
Pressure Range (psig)
0 to 25 psig
Accuracy
± 1.0% of span
Output Signal
4 mA to 20 mA, 2-Wire and Hart® Signal
Process Connection
Nose Cone
Electrical Connection
Standard polyurethane (PUR) cable
Assets
Product Specifications|Temperature Ranges|Additional Information|Options and Accessories|Applications|Limitations Which Apply Are|Prop 65 Warnings
Product Specifications
▲| Type | Submersible Level Transmitter |
| Series | 611 |
| Pressure Range | 0 to 25 psig |
| Accuracy | ± 1.0% of span |
| Note for Accuracy | Includes non-linearity, hysteresis, zero offset and end value deviation per IEC 61298-2 Accuracy after turndown via HART®, ≤ ±1.25% of scaled span (0.75% optional) Temperature sensor 14 ºF to 176 ºF (-10 ºC to 80 ºC): ≤ ± 3.3 ºF. |
| Output Signal | 4 mA to 20 mA, 2-Wire and Hart® Signal |
| Process Connection | Nose Cone |
| Electrical Connection | Standard polyurethane (PUR) cable |
| Options | Cable Clamp |
| Style | Level Transmitter |
| Approximate Weight | 10.6 oz |
| Storage Temperature (Min.) | -40 ºF
-40 ºC |
| Storage Temperature (Max.) | 176 ºF
80 ºC |
| Optional Accuracy | ± 0.5% of span |
| Optional Housing Material | 318 LN |
| Warranty | 3 yr |
| Stability | ≤ ± 0.1% of span per year |
| Switch on Time (Output signals without HART®) | ≤ 150 ms |
| Switch on Time (Output Signals with HART®) | ≤ 250 ms |
| Settling Time (Output Signals without HART®) | ≤ 100 ms |
| Settling Time (Output Signals with HART®) | ≤ 250 ms |
| Durability | > 100,000,000 full scale cycles |
| Power Requirement | 4mA to 20 mA: 8 Vdc to 36 Vdc 4 mA to 20 mA and HART®: 12-36 Vdc 0.1 to 2.5 Vdc: 3.6 - 36 Vd |
| Load Limitations | 4 mA to 20 mA: ≤ (Vpower - 8 V) / 0.022 A 4 mA to 20 mA and HART®: ≤ (Vpower - 9.6 V) / 0.022 A |
| Proof Pressure | 5 Times Range |
| Measuring Element | Cap: Polyvinylidene Fluoride (PVDF) Sensor: 316 stainless steel, options Hastelloy C-276 Cable: Polyurethane, optional FEP |
| Connection Material | 316 Stainless Steel |
| Housing Material | 316 Stainless Steel |
| Environmental Rating | Ingress Protection (IP68) |
| Electromagnetic Rating | European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Electrical Protection | Reverse polarity protection, short circuit and resistance to overvoltage :DC 40V and increased overvoltage for lightning protection. Normal discharge current ≥ 10 kA, Rise time 8/20 µs |
| Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | 4 g |
| Cable Length | 150 ft |
Temperature Ranges
▲| Compensated Temperature Range | 32 to 176 ºF
0 to 80 ºC |
| Note for Compensated Temperature Range | Effect ± 0.01%/ºF for zero and span |
| Standard Media Temperature Range | 14 to 122 ºF
-10 to 50 ºC |
| Optional Media Temperature Range | -40 to 176 ºF
-40 to 80 ºC |
Additional Information
▲| Additional Information |
|
Options and Accessories
▲| Options and Accessories |
|
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |