Intrinsically Safe Submersible Pressure Transmitter, 0 psig to 25 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, Nose Cone, 20 ft PUR Cable
Featured Specifications
Pressure Range (psi)
0 to 25 psig
Accuracy
± 0.25% full scale (BFSL)
Process Connection
Stainless Steel
Electrical Connection
20 feet Standard Polyurethane (PUR) Cable
Assets
Product Specifications|Additional Information|Options and Accessories|Note|Applications|Prop 65 Warnings
Product Specifications
▲| Type | Liquid Level Transmitter |
| Series | 627 |
| Approximate Weight | 7 oz |
| Storage Temperature (Min.) | 14 ºF
-10 ºC |
| Storage Temperature (Max.) | 140 ºF
60 ºC |
| Housing Material | 316 Stainless Steel |
| Output Signal | 4 mA to 20 mA, 2-wire |
| Accuracy | ± 0.25% full scale (BFSL) |
| Note for Accuracy | For ranges ≥ 150 inH2O (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors). |
| Environmental Rating | Ingress Protection (IP68) |
| Electrical Connection | 20 feet Standard Polyurethane (PUR) Cable |
| Connection Material | Stainless Steel |
| Pressure Range | 0 to 25 psig |
| Stability | ≤ ±0.2% full scale for 1 year, non-accumulating |
| Response Time | ≤1 ms |
| Service Life | > 100,000,000 load cycles |
| Compensated Temperature Range | 32 to 122 ºF
0 to 50 ºC |
| Note for Compensated Temperature Range | Zero effect is ±0.011% full scale/ºF within compensated range Span effect is ±0.011% full scale/ºF within compensated range |
| Media Temperature Range | 14 to 140 ºF
-10 to 60 ºC |
| Ambient Temperature Range | 14 to 140 ºF
-10 to 60 ºC |
| Power Requirement | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) |
| Proof Pressure | 2 Times Range |
| Burst Pressure | 3 Times Range |
| Diaphragm and Cap Material | 316 Stainless Steel |
| Measuring Element | 17-4PH stainless steel for 0 psig to 350 psig |
| Cable Material | Polyurethane, Fluorinated Ethylene Propylene |
| Electrical Protection | Reverse polarity, over-voltage and short circuit protected |
| Cable Length | 20 ft |
| Electromagnetic Rating | Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Load Limitations | ≤ (VPower-10)/0.020 Amp-(0.043 Ω x length of cable in feet) |
Additional Information
▲| Additional Information | NOSHOK 627 Series transmitters are Canadian Standards Association approved for use in hazardous location applications as follows:
|
Options and Accessories
▲| Options and Accessories |
|
Note
▲| Note | Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. |
Applications
▲| Application |
|
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |