About
Intelligent Line Powered Panel Meter Analog, 85-265 VAC, 90-265 VDC, SunBright, 0.6 in, Dual Line, 6 Digits, Red LED, 4 Relays & 4-20 mA Output
Featured Specifications
Power
85-265 Vac 50/60 Hz or 90-265 Vdc, 20 W max
Display Brightness
SunBright, 0.6 in, Dual Line, 6 Digits, Red LED
Option Cards
4 Relays & 4-20 mA Output
Assets
Product Specifications
▲| Note | Except where noted, all specifications apply to operation at +25°C |
| Memory | All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost |
| Weight | 9.5 oz (269 g) |
| Display | Dual-Line 6-Digit Display, 0.6" (15 mm) & 0.46" (12 mm) |
| Accuracy | ±0.03% of calibrated span ±1 count; square root & programmable exponent accuracy range: 10-100% of calibrated span |
| Altitude | Up to 2,000 meters |
| Humidity | 0 to 90% non-condensing |
| Filtering | 0 to 25 seconds, selectable |
| Indications | 4 front-panel alarm status LEDs (1 per relay/set point), independent of relay status; available even on meters without relays installed |
| Keypad Type | 4 front panel buttons |
| Update Rate | 5/second (200 ms) |
| User Inputs | F4 digital input — remote operation of front-panel buttons, relay acknowledge/reset, max/min reset |
| Warranty | 3 yr |
| Option Cards | 4 Relays & 4-20 mA Output |
| Input Signals | Field selectable: 0-20 mA, 4-20 mA, ±10 V (0-5 V, 1-5 V, 0-10 V) |
| Linearization | 2 to 32 points (PV1); 2 to 8 points (PV2, dual-scale) |
| Input Overload | Current input protected by internal resettable fuse, 30 VDC max; auto-resets after fault clears |
| Product Series | IDE30 |
| Min/Max Reading | Captures and stores min/max measurement |
| Power Requirement | 85-265 Vac 50/60 Hz or 90-265 Vdc, 20 W max |
| Sensor Excitation | Isolated 24 Vdc @ 200 mA Transmitter Power Supply |
| Temperature Drift | Input: 0.005%/°C max (0 to 65°C ambient), 0.01%/°C max (-40 to 0°C ambient) |
| Display Brightness | SunBright, 0.6 in, Dual Line, 6 Digits, Red LED |
| Environmental Rating | UL Type 4X, NEMA 4X, IP65 (front panel only); panel gasket provided |
| Electrical Connection | Screw terminals at back of case; accepts 12 to 22 AWG wire |
| Normal Mode Rejection | Greater than 60 dB at 50/60 Hz |
| Electromagnetic Rating | EN 55022 Class A emissions; EN 61326-1 & EN 61000-6-2 immunity; CE compliant |
| Power Resistance [Max] | Output loop resistance: 10-700 Ω (24 VDC internal supply); 100-1200 Ω (35 VDC external supply) |
| Power Consumption [Max] | AC version: 20 W max; DC version: 15 W max |
| Storage Temperature Range | -40 °F to 185 °F (-40 °C to 85 °C) |
| Operating Temperature Range | -40 °F to 149 °F (-40 °C to 65 °C) |
Applications
▲| Application |
|
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |