About

Intelligent Pressure Transmitter IO Link, 0 to 160 bar gauge, ±0.50% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, one switching output (PNP), IO-Link 1.1, G 1/4 A male ISO 1179-2, M12 x 1 4 pin with integral indication

Featured Specifications

Accuracy

0.50% full scale

Output Signal

IO-Link v 1.1 (1 configurable output, PNP)

Process Connection

G 1/4 A Male ISO 1179-2

Electrical Connection

M12 x 1 (4-pin)

Product Specifications

▲
Pressure Range
0 barg to 160 barg (0 psig to 2320 psig)
Service Life
100,000,000 cycles (MTTF > 100 years)
Ambient Temperature Range
-22 to 212 ºF -30 to 100 ºC
Compensated Temperature Range
-4 to 176 ºF -20 to 80 ºC
Media Temperature Range
-22 to 212 ºF -30 to 100 ºC
Humidity
45 - 75% r.h.
LED Status
Green: Operation, Yellow: Warning, Red: Error
Current Consumption
≤25 mA, ≤0.3 A including switching current (one switching output)
Proof Pressure
2 Times
Measuring Element
316L, PH grade Stainless Steel
Housing Material
316L Stainless Steel
Connection
PBT GF30, 316L Stainless Steel
Environmental Rating
IP65 and IP67 per IEC 60529
Electromagnetic Rating
RFI, EMI and ESD protection
Electrical Protection
Reverse polarity, over-voltage and short circuit protected
Shock
100 g, 6 ms, mechanical
Vibration
25 g, 10 to 2,000 Hz
Weight
2.8 oz

Output Parameters

▲
Output Number
1 output, adjustable via IO-Link (PNP)
Output Function
Normally open, normally closed, window and hysteresis (adjustable via IO-Link)
Switching Current
Max 250 mA
Response Time
<5 ms
Zero Point Offset
Max 3% of span (via IO-Link)
Damping
0 ms to 65 ms (via IO-Link)
Switch On Time
1 s
Switching Voltage
Power Supply - 1 V
Accuracy
0.50% full scale
Long Term Drift
≤0.10% of span (per 1 year)
Temperature Error
≤1.5% of span
Temperature Coefficients
Mean TC zero point/Mean TC span: ≤ 0.10% of span/10K from -22 °F to 212 °F (-30 °C to 100 °C)

Applications

▲
Application
  • Hydraulics & pneumatics
  • Automation engineering
  • Pumps & compressors
  • Water & wastewater

Limitations Which Apply Are

▲
Limitations Which Apply Are
These units must be operated within the cataloged environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Prop 65 Warnings

▲
Prop 65 Warnings
⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov