Nominal Span Adjustment Range

Mounting Application

Connection/Termination

Accuracy

NOSHOK, Inc.

550 Series ES2 Slimline Level Transmitters

Series Overview

Pressure Test Fixture, standard mount fixture
Part NumberNominal Span AdjustmentAccuracyMounting ApplicationConnection/Termination
1316038 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
1315668 0 to 5 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
1315673 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
1315308 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)
1316033 0 to 5 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5503-3-05 0 to 5 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5502-3-05 0 to 5 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
5503-3-15 0 to 15 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5502-3-10 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
5502-3-30 0 to 30 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
5502-3-15 0 to 15 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
5502-3-50 0 to 50 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Standard Mount (Insulated Wall Up to 4.5 in./114 mm; or Adapter for Non-KING "Short" Shell) Cable with Integral Molded Connector (M12)
5503-3-30 0 to 30 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5503-3-50 0 to 50 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5503-3-10 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell) Cable with Integral Molded Connector (M12)
5501-3-30 0 to 30 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)
5501-3-05 0 to 5 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)
5501-3-10 0 to 10 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)
5501-3-15 0 to 15 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)
5501-3-50 0 to 50 psig Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) Short Mount (Single Wall, Non-Insulated Tank) Cable with Integral Molded Connector (M12)