Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Part Number |
Description |
Pressure Range |
Accuracy |
Process Connection |
Electrical Connection |
CAD |
---|---|---|---|---|---|---|
PT41-87000psig-1-2-6-16 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-87000psig-1-2-6-8 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-87000psig-1-2-6-14 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-87000psig-1-2-6-18 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-87000psig-1-2-6-25 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-87000psig-1-2-6-36 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-87000psig-1-5-6-3 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-87000psig-1-5-6-16 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-87000psig-1-5-6-8 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-87000psig-1-5-6-14 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-87000psig-1-5-6-18 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-87000psig-1-5-6-25 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-87000psig-1-5-6-36 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-87000psig-2-1-6-3 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-87000psig-2-1-6-16 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-87000psig-2-1-6-8 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-87000psig-2-1-6-14 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-87000psig-2-1-6-18 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-87000psig-2-1-6-25 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-87000psig-2-1-6-36 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-87000psig-2-2-6-3 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-87000psig-2-2-6-16 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-87000psig-2-2-6-8 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-87000psig-2-2-6-14 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-87000psig-2-2-6-18 | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 87000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 87000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |