MENU
NOSHOK'S COVID-19 Response
  • Current and voltage outputs available
  • 316 Stainless Steel wetted parts
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • 3A Certified
  • CE compliant to suppress RFI, EMI and ESD
1 - 14 of 14 | Results Per Page | View | Unit of Measure
1 
Clear Filter

Type

Clamp Size (in)

Full Scale Best Fit Straight Line (BFSL) Accuracy (±) (%)

Pressure Range

Output Signal

Electrical Connection

Part Number

Description

Clamp Size

Housing Material

Full Scale Best Fit Straight Line (BFSL) Accuracy (±)

Pressure Range

N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), -30 inHg to 100 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A Connection with ISO 4400 1/2 in. National Pipe Thread (NPT) Conduit N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A -30 inHg to 100 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 5 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with 36" Integral Cable N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 5 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 15 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 60 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 60 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 100 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 100 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 150 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 150 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 160 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 160 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 200 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 200 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 300 psig
N/A 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with 20 ft Integral Cable N/A 1-1/2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 300 psig
N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) N/A 2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 15 psig
N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 200 psig, 4 to 20 mA Output Sanitary Transducer with 20 ft Integral Cable N/A 2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 200 psig
N/A 2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 300 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) N/A 2 in N/A 316 Stainless Steel N/A 0.125 %0.25 % N/A 0 to 300 psig
1 - 14 of 14 | Results Per Page | View | Unit of Measure
1