• Direct reading by volume or weight
  • Nonvolatile datapack iButton memory
  • Provides 24 Vdc transmitter excitation
  • Dual serial communications ports
Unit of Measure

Specifications

Type

N/A LP2 Single Tank Level Indicator

Series

N/A 4640

Environmental Operating Temperature [Min]

N/A 0 ºC30 ºF

Environmental Operating Temperature [Max]

N/A 50 ºC120 ºF

Full Scale Accuracy (±)

N/A 0.048 %

Typical Full Scale Accuracy (±)

N/A 0.024 %

Frequency [Max]

N/A 60 Hz

Frequency [Min]

N/A 50 Hz

Alternating Current (AC) Voltage

N/A 100 to 240 V
Power Rating1 N/A 25 W

Resolution

N/A ± 0.024% Full Scale Maximum (± 0.004 mA)

Memory

N/A Non-Volatile 64 kbit Memory iButton

Digital Readout

N/A Alphanumeric 0.3173 in. (8 mm) 16-Character x 2-Line Liquid Crystal Display (LCD); Numeric 8-Digit (0-99,999,999 Maximum)

Power Output

N/A 24 V

Communication

N/A Two (2) Serial EIA RS-485 Ports; Two Wire Multidrop

Nominal Input Impedance (Resistance)

N/A 120 O

Keypad Type

N/A Membrane Numeric Keypad, Five (5) Function Keys, Positive Tactile Response

Optional Enclosures

N/A 304 Stainless Steel

Note for Enclosure Options

N/A Engineered FRP and Stainless Steel enclosures listed are splash-proof and UL-listed. Intended to meet NEMA 4X. Includes Hubbell cable relief fittings (3), suitable for splash-tight installation. Flush mount option must be ordered with 4243 iButton Datapack.

Configuration

N/A L/H SETPT1 Low, SETPT2 High

Input Direct Current (DC)

N/A 4 to 20 mA

Enclosure

N/A 14 gauge Stainless Steel Enclosure; UL 50 Types 4, 4X, 12, 13; Hinged Cover with Dual Latching Screw Lugs

24 Volt Direct Current (DC) Output (Transmitter Excitation)

N/A The LP2 tank indicator incorporates an internal 24 Vdc supply that can be used to power the signal loop. A pair of shunt/jumpers are used to enable or disable this voltage supply across the signal input terminals. If an external power supply is used (occasionally tied through the I/O card of a PLC), the internal 24 Vdc can be easily disabled at the LP2.

Application

Application

N/A Tank Level Indication

Options and Accessories

Options and Accessories

N/A 4223-S-1-1: iButton Datapack with Field Installed Kit

4223-S-1-2: Factory Installed iButton Datapack

Baud Rate: 9,600, 19,200 (Default)

Adapter Plate

N/A 5936-1: Adapter plate for replacing 5,300 or 8,900 Single Tank Digital Indicators and 5,100 Multiple Tank Digital Indicators with LP2 Tank Displays.

Replacement Fuses/Terminal Connectors

N/A 7469-24-0: 500 mA 250 V GMA Fast Acting Fuse 5 x 20 mm, Processor Board, 5-Pack

7469-24-4: 2.5 A 250 V GMA Fast Acting Fuse 5 x 20 mm, Power Supply, 5-Pack

5858-2: 2-Terminal Connector

5858-3: 3-Terminal Socket Connector

5858-12: 12-Terminal Socket Connector

Features

Tank Level Display

N/A The LP2 single tank indicator features a keypad for entering of specific gravity (for auto density compensation) and supervisory password protection modes. An alphanumeric LCD panel provides 10-character tank identification with 8-digit display value and current density selection.

Note: The specific gravity (density) displayed is either the preprogrammed default, a value that is entered through the keypad or sent over the serial network. Refer to section on Data Acquisition and Network Connectivity.

Flush Mount Package

N/A The LP2 single tank indicator is also available in a flush panel mounted housing. All connections are situated at the rear of the housing to facilitate installation in a control console or instrument enclosure. The front display panel has a low rise profile of less than 3/16 inch (4.7 mm) when installed.

Application Programming

N/A The LP2 indicator references a capacity profile to correlate transmitter output to actual tank geometry. This profile plus additional application details are factory programmed into an innovative nonvolatile Datapack iButton memory module. Different units of measurement and/or specific gravity values can be assigned to each tank in the system. LP2 stores all the user selections in its Datapack iButton memory. The more critical data is restricted to read only access to prevent any possible corruption of the original factory programming.

Data Acquisition and Network Connectivity

N/A LP2 multiple tank indicators can be used to eliminate analog I/O at your PLC or PC-based control system. As data acquisition hubs, each LP2 tank level indicator resides on an expandable multidrop network. Any combination of up to 32 discrete single channel or multiple channel indicators can be installed on a simple two wire network (RS-485).

Dual serial communications ports (RS-485) can be configured for different protocols such as master/satellite, ASCII data exchange or Modbus-RTU emulation. This flexibility means that LP2 indicators can be linked to different data networks. This allows for multiple simultaneous protocols including query-response communications with a computer (or PLC), remote satellite displays or interface to a KING-GAGE® LP3 system.

LP2 indicators can be used as basic stand alone tank level indication. Combining both accuracy and reliability, they provide a complete tank level gauging solution where precise accounting of liquid inventory is needed. LP2 indicators also simplify future upgrades requiring system interconnectivity for industrial networks.

Additional Information

Additional Information

N/A The new LP2 Tank Level Indicator combines intelligent signal processing and data acquisition for seamless integration in process control. LP2 indicators will provide continuous measurement of liquid inventory in storage or processing tanks. Calculating level on the basis of hydrostatic pressure created by liquid depth, the system measures total product mass for more precise material accounting.

LP2 indicator accepts the proportional 4-20 mA signal from a liquid level transmitter. The actual sensor used to detect hydrostatic pressure (created by liquid depth) can be either electronic or pneumatic. With the latter, an electronic pressure transmitter is used to convert the sensor’s pneumatic signal into 4-20 mA output (using a KING-GAGE® D/P Module or D/P Transmitter).

LP2 indicators express tank level directly in engineering units. The indicator references a capacity profile to correlate transmitter output to actual tank geometry. The indicator then formats the resulting value directly as the total weight or volume of liquid in the tank. There are no user conversion factors involved or scaling points to enter. All application details are factory programmed into an innovative nonvolatile modular memory called the Datapack iButton.

Whether mounted at the tank as a local display or networked to a central control station, LP2 indicators offer a complete system solution. Their rugged design incorporate many valuable features that simplify installation while ensuring long-term reliability.

Warnings

Product Warranty

N/A All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase.

Repair Services Warranty: 90 days limited warranty.

Prop 65 Warnings

N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • 1 Fused internally for 2.5 A 120/250 V