Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Pressure Transmitter |
Connection Type |
N/A Male National Pipe Thread (MNPT) |
Weight |
N/A 12 oz |
Storage Temperature [Min] |
N/A -300 ºC-22 ºF |
Storage Temperature [Max] |
N/A 100 ºC212 ºF |
Pressure Range |
N/A 0 to 8,000 psig |
Housing Material |
N/A 316 Stainless Steel |
Connection Size |
N/A 1/4 in |
Connection Size (Search Only) |
N/A 1/4 in |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
N/A 0.25 % |
Output Signal |
N/A 4 mA to 20 mA, 2-Wire |
Electrical Connection |
N/A 1/2 in. NPT male conduit with 6 ft integral cable |
Environmental Rating |
N/A Ingress Protection (IP65) to Ingress Protection (IP67) dependent upon electrical connection |
Series |
N/A Stainless Steel Threaded Connection |
Connection Material |
N/A 316 Stainless Steel |
Absolute Pressure Range |
N/A 0 to 100 psia |
Stability |
N/A ≤ ±0.2% full scale for 1 year, non-accumulating |
Response Time |
N/A ≤1 ms |
Service Life |
N/A > 100,000,000 Load Cycles |
Compensated Temperature Range |
N/A 32 to 176 ºF0 to 80 ºC |
Note for Compensated Temperature Range |
N/A
Zero effect is ±0.011% full scale/ºF within compensated range Span effect is ±0.011% full scale/ºF within compensated range |
Media Temperature Range |
N/A -40 to 212 ºF-40 to 100 ºC |
Ambient Temperature Range |
N/A -22 to 176 ºF-30 to 80 ºC |
Power Requirement |
N/A
10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Measuring Element |
N/A 623 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel and Elgiloy for ranges 0 psig to 500 psig and higher |
Electrical Protection |
N/A Reverse polarity, over-voltage and short circuit protected |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 |
N/A 1,000 g |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A 20 g |
Warranty |
N/A 3 yr |
Current for 4 to 20 Milliampere (mA) |
N/A 0.020 A |
Resistance for 1 to 5 Direct Current (DC) Voltage, 3-Wire |
N/A ≥ 10,000 O |
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Application |
N/A
|
Additional Information |
N/A
NOSHOK 621 and 622 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
|
Options and Accessories |
N/A 20 foot cable/lead attached to 1/2" NPT Male Conduit w/ 6 foot integral cable |
Assembly Options |
N/A NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. |
Digital Indicators |
N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
Pressure Snubbers - Piston Type |
N/A
|
Pressure Snubbers - Sintered Type |
N/A
|
Steam Syphons |
N/A
|
Swivel Adapters |
N/A
|
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|