Type |
N/A TeleSensor Level Transmitter |
Series |
N/A 92 |
Flange Size |
N/A 3 in |
Flange Material |
N/A 316 Stainless Steel |
Wetted Material |
N/A
Fluorocarbons (FKM) O-ring, Titanium diaphragm, commercially pure. Optional diaphragm materials: Silicone rubber Mounting flange options: 316L Stainless, Polyvinyl Chloride (PVC), brewery special flange |
Fittings |
N/A Swagelok; (4) 1/4 in. tube (Compatible with Copper or Poly Tubing) |
Air Consumption |
N/A Total air consumption of sensor package (including sensor control) is less than 10 ft³/h or 0.16 scfm. |
Sensor Pressure Range |
N/A Sensor is a 1:1 pneumatic force balance diaphragm capable of repeating hydrostatic pressure as an equivalent pneumatic output. Functional pressure limit is 130 psi (or 3,598 inches at 1.00 specific gravity) determined by supply pressure (35 to 150 psi) less 20 psi. |
Sensitivity |
N/A Less than 0.001 psi (± 0.02 inH2O/ 0.508 mmH2O) |
Repeatability |
N/A Better than ± 0.002 psi (± 0.05 inH2O /1.27 mmH2O) |
Primary Accuracy |
N/A ± 0.007 psi (± 0.2 inH2O/0.508 mmH2O) |
Operating Limit (Maximum Pressure) |
N/A Pressure above 300% nominal range (over range) will result in damage to the transmitter (200% may cause a shift in calibration). Burst pressure is 200 psi and will cause catastrophic and physical failure of the pressure element. |
Depth Measurement [Max] |
N/A 1,937 inH2O49.0 mH2O |
Tank Flange Mounting |
N/A The basic configuration is designed for mounting to any typical outlet near the bottom of the tank. It features a pipe flange connection (2", 3", or 4" class 150 ANSI). Since the TeleSensor sensing diaphragm responds to the pressure due to the head of liquid in the tank, the mounting location determines the starting level measurement point. Owing to the direct contact, all wetted materials should be selected based on compatibility with the tank’s contents. Standard diaphragms are titanium. Flange connectors are available in various materials as well. The rugged design of the TeleSensor tank unit is remarkably easy to maintain. |
Transmitter Signal Loop |
N/A As is typical of two wire transmitters, electrical power to the signal loop is supplied through twisted pair cable. Excitation voltage (+V) is provided by the receiving device or from a separate Vdc power supply installed in the loop. The actual voltage necessary for operation of the system will depend upon the overall load resistance of the loop. In most applications, the KING-GAGE® Digital Indicator or LevelBAR indicator provide 24 Vdc excitation to power the transmitter signal loop. |
Explosion Hazard Use (Zone One or Division One) |
N/A The TeleSensor requires no electrical energy for operation when using the 860 Sensor Control. It is possible to configure the tank level system without zener barriers or intrinsic safety provisions. The pneumatic signal may be routed to beyond the hazard zone (1,000 feet or more) to an indicator or transmitter. |
Pneumatic Operation |
N/A TeleSensor diaphragm unit is paired with a Sensor Control regulator to provide the continuous 1 CFH (cubic foot per hour) air flow to the underside of the diaphragm to attain pneumatic balance pressure. Constant back pressure regulation maintains linear 1:1 response throughout the entire operating range to ensure pneumatic pressure is directly equivalent to the hydrostatic head of liquid in the tank. |
Compressed Air Supply |
N/A Operation of the AcraSensor requires a compressed air/gas source providing supply pressure of 35-150 psig (2.4-10.3 bar). Pneumatic components require instrumentation-grade compressed air that is clean, dry and oil-free to ensure trouble free performance. |
Operating Temperature [Min] |
N/A 0 ºC30 ºF |
Operating Temperature [Max] |
N/A 149 ºC300 ºF |
Application |
N/A
|
Tank Gauging Applications |
N/A
Acting on the force balance principle, a pneumatic sensor generates air pressure equivalent to the hydrostatic force created by liquid depth. This pneumatic pressure is directed into the D/P transmitter. Pressure is converted to an electronic 4-20 mAdc output proportional to liquid depth. Twisted pair cabling is used to form the signal loop through which the remote indicator receives the transmitter output. The KING-GAGE® indicators shown in these system views correlate the transmitter output to total volume or weight of tank contents. This is determined by using a pressure versus capacity listing corresponding to the actual tank dimensions. The diaphragm unit is generally paired with the 868 D/P Sensor Control with integral transmitter. This converts the pneumatic isolation pressure to a proportional 4-20 mAdc signal suitable for process control or remote level indication. The standard TeleSensor + 868 D/P package combines accuracy, rugged durability, reduced maintenance, and long term stability for liquid level tank gauging. |
Service and Replacement Parts |
N/A
7333-10: Replacement filter element 7334-2: SafeGard service kit 7334-9: Air control section kit 7879-20: Vent generator 9316-4: O-ring for D/P top plate (868) |
860 Series Sensor Control |
N/A
|
868 Series Differential Pressure Sensor Control |
N/A
|
3-Tube Cable (Replacement or Non-Standard Lengths) |
N/A
Use for interconnection between AcraSensor and Sensor Control 1766-15: Cable, 15 ft (4.5 m) total length, trimmed 8014-X: Cable quantity discount, minimum purchase 50 feet, X = Total Length |
Differential Pressure Capsule Replacement |
N/A
Replacement D/P capsule (sensor/transmitter assembly) for Model 868 D/P Sensor Controls. Signal input connection is 1/4 NPT - part numbers below do not include fitting. S-1565-1-5-1: D/P Replacement Capsule Kit (0-2 psid) S-1565-1-0-1: D/P Replacement Capsule Kit (0-5 psid) S-1565-1-1-1: D/P Replacement Capsule Kit (0-10 psid) S-1565-1-2-1: D/P Replacement Capsule Kit (0-15 psid) S-1565-1-3-1: D/P Replacement Capsule Kit (0-30 psid) S-1565-1-4-1: D/P Replacement Capsule Kit (0-50 psid) |
TeleSensor Replacement/Service Parts |
N/A
Replacement/Service Parts for new 922/923/924 Series or 5373/5374 Series TeleSensor 1747-30: O-Ring (Fluorocarbons (FKM)); Internal TeleSensor 6448-12-5: Diaphragm (Silicone Rubber); 2-Pack 7904-2: Titanium Diaphragm Assembly (with Fluorocarbons (FKM) O-Ring) 7904-1: Titanium Diaphragm Assembly (with Silicone O-Ring) Replacement/Service Parts for existing 403/404 Series or 422/423/424 Series TeleSensor diaphragm units 6438: Polytetrafluoroethylene (PTFE) Gasket (External TeleSensor) 6438-11: Polytetrafluoroethylene (PTFE) Gasket (Internal TeleSensor) 6448-4: Transmitter Diaphragm, Kel-F 6448-13: Transmitter Diaphragm, 316 Stainless Steel (SS) 6448-22: Transmitter Diaphragm, Titanium 5051-204: Kel-F Diaphragm Capsule Assembly 0 ºF - 250 ºF (Internal TeleSensor) 5051-213: 316 SS Diaphragm Capsule Assembly 0 ºF - 250 ºF (Internal TeleSensor) 5051-222: Titanium Diaphragm Capsule Assembly 0 ºF - 110 ºF (Internal TeleSensor) |
Rugged and Reliable Measurement |
N/A
These unique pneumatic sensors detect level by sensing hydrostatic pressure created by liquid depth. Acting on the force balance principle, a sensitive diaphragm is exposed to the liquid contents of the tank. Compressed air within the sensor creates a pneumatic pressure that balances the force of the liquid acting against the diaphragm. This compensating pneumatic pressure is directly proportional to the depth of liquid in the tank. The pneumatic force balance technique is virtually free from long term drift, hysteresis and temperature sensitivity unlike strain measurements (including load cells) since mechanical deflection of the diaphragm is not directly measured. The compensating pneumatic balance pressure which effectively isolates the sensor is converted to a proportional 4-20 mAdc signal or can be directly output to a suitable gauge. In actuality, the sensor is measuring the mass (weight) of fluid matter that can be correlated to units of standardized volume. |
Additional Information |
N/A
|
Product Warranty |
N/A
All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase. Repair Services Warranty: 90 days limited warranty. |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Note |
N/A
3-tube cable (15 ft./4.5 m) included with shipment. 4" flange has a 8 bolt circle. 2" and 3" flanges have a 4 bolt circle. All flanges are 150 lb. ANSI. Special 3" 304 Stainless Steel brewery flange is available, consult factory. |
Application Notes |
N/A Mounting flange and diaphragm are wetted surfaces requiring compatibility with process media. Location of the Sensor Control regulator should generally be no greater than 50 feet (15 m) from the TeleSensor unit. The sensor includes 15 feet (4.5 m) of bundled 3-tube cable for the pneumatic interconnections with the Sensor Control. Distances greater than 50 feet may increase response time of sensor to changes in liquid level in the tank. |