About
- Easy programming and range adjustment without test pressure via on-board display
- 10:1 turn down
- Active temperature compensation
- 360º rotatable display
- Hart® protocol output available
Featured Specifications
Adjustable Pressure Range (inH₂O)
47 to 470 inH₂O
Output Signal
4 mA to 20 mA, 2-Wire and Hart® Signal
Process Connection
Anderson Negele Type SL Long - 6 in.
Electrical Connection
PG9 Cable Gland
Assets
Product Specifications|Additional Information|Digital Indicators|Applications|Limitations Which Apply Are|Prop 65 Warnings
Product Specifications
▲| Type | Sanitary Pressure Transmitter |
| Weight | 3.3 lb |
| Housing Material | 304 Stainless Steel |
| Output Signal | 4 mA to 20 mA, 2-Wire and Hart® Signal |
| Electrical Connection | PG9 Cable Gland |
| Accuracy | 0.1% of Adjusted Span |
| Environmental Rating | Ingress Protection (66) (National Electrical Manufacturers Association (NEMA) 4X), Ingress Protection (68) (National Electrical Manufacturers Association (NEMA) 6) optional |
| Series | 20 |
| Process Connection | Anderson Negele Type SL Long - 6 in. |
| Adjustable Pressure Range | 47 to 470 inH2O |
| Connection Material | 316 Stainless Steel |
| Stability | < 0.1%/year |
| Adjustment | By 3 push buttons on display or optional Hart® signal |
| Response Time | <150 ms |
| Service Life | 10 yr |
| Measuring Element | 316 Stainless Steel (Hastelloy C, Tantalum or Goldplated Optional) |
| Temperature Range for 45 Minute ºF | 293 ºF |
| Temperature Range for 45 Minute ºC | 145 ºC |
| Direct Current (DC) Voltage | 12 to 36 V |
| Options | Transparent Cover (for Display) (TC) |
| Warranty | 3 yr |
Additional Information
▲| Additional Information |
|
Digital Indicators
▲| Digital Indicators | NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |