About
Cage Protected Submersible Transmitter, Wetted Materials: 316 SS, 0 psig to 15 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 50 ft PUR Cable
Featured Specifications
Accuracy
± 0.25% full scale (BFSL)
Pressure Range
0 to 15 psi
Output Signal
4 mA to 20 mA, 2-wire
Electrical Connection
50 feet Standard Polyurethane (PUR) Cable
Assets
Product Specifications|Related Items|Additional Information|Options and Accessories|Applications|Limitations Which Apply Are|Prop 65 Warnings
Product Specifications
▲| Type | Submersible Level Transmitter |
| Series | 613 |
| Pressure Range | 0 to 15 psi |
| Accuracy | ± 0.25% full scale (BFSL) |
| Note for Accuracy | Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors. |
| Output Signal | 4 mA to 20 mA, 2-wire |
| Electrical Connection | 50 feet Standard Polyurethane (PUR) Cable |
| Style | Level Transmitter |
| Storage Temperature (Min.) | -22 ºF
-30 ºC |
| Storage Temperature (Max.) | 175 ºF
80 ºC |
| Stability | ≤ ± 0.2% full scale for 1 year, non-accumulating |
| Response Time | ≤1 ms |
| Service Life | > 100,000,000 load cycles |
| Temperature Measurement | Optional PT100, 4-wire per International Electrotechnical Commission (IEC) 60751 |
| Power Requirement | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire) 5 Vdc to 30 Vdc (0.5 Vdc to 2.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
| Load Limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire |
| Proof Pressure | 2 Times Range |
| Burst Pressure | 4 Times Range |
| Measuring Element | Cage seal: All 316 stainless steel Cable: polyurethane, optional FEP |
| Connection Material | 316 Stainless Steel |
| Housing Material | 316 Stainless Steel |
| Environmental Rating | Ingress Protection (IP68) |
| Electromagnetic Rating | Built to suppress RFI, EMI, and ESD, Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Electrical Protection | Reverse polarity protection, short circuit and optional lightning protection per European Standards (EN) 6100-4-5; 1.5J |
| Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | 100 g |
| Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | 15 g |
| Weight1 | 3.2 lb |
| Compensated Temperature Range | 32 to 122 ºF
0 to 50 ºC |
| Note for Compensated Temperature Range | Effect ± 0.01%/ºF for zero and span |
| Media Temperature Range | 14 to 122 ºF
-10 to 50 ºC |
| Warranty | 3 yr |
| Cable Length | 50 ft |
Additional Information
▲| Additional Information |
|
Options and Accessories
▲| Options and Accessories |
|
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |