About

Industrial RTD Accuracy: ±0.12% @ 0 °C, Class B PT100 2-Wire, 1/2 NPT Sliding Compression Fitting, M12 x 1 (5 Pin) 4.5 Stem, 2.5 Immersion, 1/8 Diameter

Featured Specifications

Operating Temperature [Min]

-330 ºF

Operating Temperature [Max]

1,100 ºF

Accuracy

±0.12% (±0.3 ºC) at 0 ºC, Class B

Element Type

Probe

Circuit Types

Single, 2-Wire

Electrical Connection

M12 x 1 (5-Pin) - Single Circuit Types Only

Assets

▼

Product Specifications

▲
Type
Probe
Series
900
Process Connection
1/2 in" Male National Pipe Thread (MNPT) with sliding compression fitting - Add 2" to stem length for this option. If installing with thermowells, Process Connection option 48 or 61 must be selected
Temperature Range [Min]
-330 ºF
Temperature Range [Max]
1,100 ºF
Accuracy
±0.12% (±0.3 ºC) at 0 ºC, Class B
Circuit Types
Single, 2-Wire
Electrical Connection
M12 x 1 (5-Pin) - Single Circuit Types Only
Standard Finish [Max]
32 micro-inches maximum
Pressure Ratings for Tube
500 psi
Resistance Temperature Device (RTD) Element
PT100 Ω at 32 ºF (0 ºC), α=0.00385 International Electrotechnical Commission (IEC 751)
Lead Wires
Stranded 22 AWG standard, Polyvinyl Chloride (PVC) or Polytetrafluoroethylene (PTFE) Insulation
Self-Heating
50 mW / ºC Typical in Moving Water
Insulation Resistance
Single Element Probes: 100 mega Ω/min. at 500 Vdc, Leads to Case
Dual Element Probes: 100 mega Ω/min. at 100 Vdc, Between Element and Leads to Case
Transition
Sheath to Wire Transition Maximum Temperature 266 ºF (130 ºC)
Warranty
3 yr

Thermowells

▲
Thermowells
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.

Additional Information

▲
Additional Information
  • A variety of fitting sizes and probe diameters are available
  • RTD PT100 Ω standard, others available
  • 2, 3 or 4-wire circuit types
  • Isolation to 500 Vdc
  • Custom designs available

Note

▲
Note
Thermowells are recommended for pressure, corrosive fluids and high velocity applications.

Applications

▲
Application
  • Chemical processing
  • Textile production
  • Automotive
  • Plastics processing
  • HVAC

Limitations Which Apply Are

▲
Limitations Which Apply Are
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Prop 65 Warnings

▲
Prop 65 Warnings
⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov