About
LP3 Series 8-Tank Level Measurement System
Featured Specifications
System
8-Tank
Input Signals Current
4 to 20 mA
External Power Requirements
110 to 120 V
External Memory
CompactFlash Type II Slot
Product Specifications
▲| Type | Tank Level Measurement System |
| Series | LP3 |
| Human Machine Interface (HMI) Display Panel | Color 10.4 in. Liquid-Crystal Display (LCD), Active Matrix Thin-Film Transistor (TFT), 640 x 480 VGA (256 Colors), Resistive Analog Touch Screen |
| Current | 2.8 A |
| System | 8-Tank |
| Input Signals Current | 4 to 20 mA |
| Input Signals | Two Wire (with 24 Vdc Excitation Option); 8-32 Input Channels |
| External Power Requirements | 110 to 120 V |
| External Memory | CompactFlash Type II Slot |
| Network Drivers | Ethernet/IP Allen-Bradley DF1 over TCP Allen-Bradley DF1/DH485 Modbus TCP/IP Kingbus ASCII |
| Serial Ports | Ethernet 10 Base-T/100 Base-TX (RJ45) RS485 (RJ12) RS232 (RJ12) Universal Serial Bus (USB) 1.1 (Type B) |
| Enclosure | Type 4X Underwriters Laboratories (UL50), Ingress Protection (IP66), 304 Stainless Steel, Hinged Latching Cover |
Applications
▲| Applications |
|
Options and Accessories
▲| Options and Accessories | 4223-M: iButton Datapack (Application programming - adding tanks) Model: 4223-M Tanks: Number of tanks Installation: Field installed kit 5680-4: LP3 programmed Compact Flash Card USER DISPLAY SETTINGS: Display settings on the LP3 can be modified by the end user, including editing the menu list of products selections, and/or specific gravities. Using the “administrator” access, they can even change the tank display arrangement on each screen page. NOTE: Unless a copy of these changes (via CF card) is provided to KING-GAGE®, A NOSHOK Company, the configuration update file we provide when revised or duplicate iButton datapacks are ordered will not replicate the edited user display settings. Model: 6580-4 Tanks: Number of tanks Installation: Field installed kit |
| Service and Replacement Parts | 5858-2: 2-Terminal Socket Connector 5858-3: 3-Terminal Socket Connector 5940-2: LP3 Display with Expansion Card (Replacement Color Touch Screen and CPU) 7469-24-0: 500 mA 250 V GMA Fast Acting Fuse 5 x 20 mm, Processor Board, 5-Pack 7469-4-6.3: 6.3 Amp 250 V Time Delay (T/250 GDC-6.3) Fuse 5 x 20 mm, Main Power Terminal Block, 5-Pack |
Features
▲| Operator Interface Human Machine Interface (HMI) | An intuitive operator display panel depicts tank levels with capability to include setpoints (alarm) monitoring. Change to the spreadsheet view for product scheduling or inventory reporting. Specific tank status details are available in a simple drilldown page for commissioning or troubleshooting. The 10.4-in. TFT color display is mounted within a Stainless Steel enclosure or as a flush mounting remote panel. |
| Signal Processing and More | LP3 system uses specialized processor modules that read the transmitter 4-20 mA signals. These inputs are digitized, scaled (linearized) and converted into volumetric or fluid mass measurement units by correlating to the specific tank geometry. This programming is pre-configured at the factory with data typically generated by dimensional information from a tank manufacturer's plan drawing. Alternatively, volumetric capacity may be taken from an available strapping table or through a physical wet calibration of a tank. While it is common to input level transmitter signals directly to analog I/O cards at the PLC, this approach requires considerable investment into the controller's programming (especially for horizontal tanks or other non-linear vessels). Since the LP3 system accomplishes the A/D conversion process, it eliminates the need for the PLC to allocate and manage I/O specifically for the transmitter inputs. More importantly, by performing the scaling functions independently, it frees up the PLC to focus on the batching and control functions (with register values loaded directly from the LP3 interface). The benefits of this approach include better data integrity with PLC performance now dedicated to more critical aspects of your process. Because data acquisition is an integral function of the KING-GAGE® LP3 system, coupled with the network connectivity including Ethernet, it is much simpler to share tank level inventory data across the process floor or even to a corporate enterprise. LP3 system software affords a high degree of accuracy and security. HMI display configurations are stored in FLASH memory while application data is isolated within an iButton datapack (non-volatile RAM). |
| Display Modes and User Menus | The LP3 system has been designed to function for plant operations personnel while providing a level of data security to assure peace of mind. There are three (3) levels of password access to permit local or remote administrative functions. LP3 Tank View Display - Up to 8 concurrent tanks graphically displayed on each screen (with support for four separate Tank View pages). Combine optional level set points for a complete monitoring solution designed to be user-friendly. A simple bargraph icon conveys tank level status at a glance. LP3 Drill Down Detail - The color touchscreen allows quick access to details including engineering units selection, tank capacity, and communications status. Configuration settings are readily visible from each tank’s detail screen. (Access to these settings is password-protected to ensure data integrity.) LP3 Inventory Status Display - Simultaneously view levels for up to 24 tanks with dynamic horizontal bar graph (representing % full status). The concise listing by tank name, product designation, and current inventory level (volume or weight) easily lends itself to production reporting. Change/Define Products - You can change the current tank product by accessing the menu listing available product designations by name and density (showing specific gravity value). The current selection is highlighted by a blue indicator button. Operator or Admin Access - If you are password entered into this access level, you can edit the product name or add a new product designation to the list (and enter a specific gravity value). Simply touch the existing text or touch an unused position to launch the on screen entry keypad. |
Warnings
▲| Product Warranty | All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase. Repair Services Warranty: 90 days limited warranty. |
| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Note
▲| Note | Complete tank gauging system includes color touch screen LCD display, signal input modules, and 24 Vdc for powering typical two wire 4-20 mAdc transmitters. Requires 100-240 Vac 50/60 Hz for operation. 304 Stainless Steel enclosure for wall mounting intended to meet NEMA 4X. Engineered Stainless Steel enclosures listed are splash-proof and UL-listed. Intended to meet NEMA 4X. Includes Hubbell cable relief fittings (3), suitable for splash-tight installation. 10.4 color touch screen display is UL listed and has IP68 rating. iButton Datapack (application programming), part number 4223, can be added separately for each tank Standard system configurations: 8-tank system; 16-tank system; 24-tank system; 32-tank system (includes HMI, analog inputs, power supply) Enhanced system configurations: 8-tank system; 16-tank system; 24-tank system; 32-tank system (includes HMI, analog inputs, analog outputs, power supply) |
Applications
▲| Application |
|