About
860 Series Polyflo; (5) 1/4" Tube Fittings and 25 to 650" SafeGard Range Pressure Output Purge Control Level Transmitter
Featured Specifications
Burst Pressure
200 psi
Fittings
Polyflo; (5) 1/4 in. Tube
Pressure Output
25 to 650 in. SafeGard Range
Repeatability
± 0.02% of Calibrated Span
Product Specifications|Pressure Ranges|Applications|Options and Accessories|Temperature Ranges|Additional Information|Warnings
Product Specifications
▲| Series | 860 |
| Type | Sensor Control Level Transmitter |
| Accuracy | ± 0.2% Full Scale (F.S.) (± 0.10% Full Scale (F.S)., typical) includes non-linearity, hysteresis and non-repeatability |
| Fittings | Polyflo; (5) 1/4 in. Tube |
| Pressure Output | 25 to 650 in. SafeGard Range |
| Thermal Effects (Over Compensated Temperature Range) | Less than 0.007% ºF (0.011% ºC) Span Shift - Sensitivity Less than 0.007% ºF (0.011% ºC) Span Shift - Zero |
| Depth Measurement [Max] | 1,937 inH2O |
| Power Supply Stability (Effect on Full Scale) | Less than 0.005% of Span Change in Output Per Volt Change at Input Terminals |
| Output Signal | 4 to 20 |
| Direct Current (DC) Power Supply Voltage (Unregulated) | 14 to 40 V |
| Repeatability | ± 0.02% of Calibrated Span |
Pressure Ranges
▲| Burst Pressure | 200 psi |
| Compressed Air Requirement | 35 psid to 150 psig supply pressure at control inlet. |
| Operating Limit (Maximum Pressure) | Pressure above 300% nominal range (overrange) will result in damage to the transmitter (200% may cause a shift in calibration). Burst pressure is 200 psi and will cause catastrophic and physical failure of the pressure element. |
| Differential Pressure Pneumatic Sensor Controls | The KING-GAGE® D/P Transmitter is also offered in a hybrid version combined with an air flow control for pneumatic sensors or downpipe (bubbler) systems. These combination units allow for direct 4–20 mA signal from the tank using the integrated differential pressure transmitter. D/P Sensor Controls are designed for use with KING-GAGE® pneumatic diaphragm sensors. The air control portion of these units creates a 1:1 pneumatic pressure directly proportional to liquid depth in the tank. Acting as a force balance, the pneumatic pressure offsets the hydrostatic pressure exerted against a diaphragm at the tank. The electronic transmitter then converts this pressure into a 4-20 mA output signal. D/P LiquiSeal™ Controls and D/P Purge Controls are used in conjunction with a downpipe (or bubble tube) extending down through the liquid contents of the tank. This type of sensor also acts as a force balance. A continuous purge of compressed air into the pipe displaces the liquid and creates a pneumatic pressure equivalent to hydrostatic head pressure. The transmitter converts this pressure into a 4-20 mA output signal. |
Applications
▲| Applications | Tank level monitoring for food and beverage. |
Options and Accessories
▲| Service and Replacement Parts | 7333-10: Replacement filter element 7334-2: SafeGard service kit 7334-9: Air control section kit 7879-20: Vent generator 9316-4: O-ring for D/P top plate (868) |
Temperature Ranges
▲| Compensated Temperature Range | 32 to 120 ºF
0 to 54 ºC |
Additional Information
▲| Additional Information |
|
Warnings
▲| Product Warranty | All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase. Repair Services Warranty: 90 days limited warranty. |
| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Applications
▲| Application | Tank level monitoring for food and beverage. |